The mac-addr is the MAC address of the device with the duplicate IP
address.
The portnum is the Brocade port that received the packet with the duplicate
IP address. The address is the packet source IP address.
Message
Level
Warning
Message
IGMP/MLD no hardware vidx, broadcast to the
entire vlan. rated limited number
Explanation
IGMP or MLD snooping has run out of hardware application VLANs. There
are 4096 application VLANs per device. Traffic streams for snooping
entries without an application VLAN are switched to the entire VLAN and to
the CPU to be dropped. This message is rate-limited to appear a maximum
of once every 10 minutes. The rate-limited number shows the number on
non-printed warnings.
Message
Level
Warning
Message
IGMP/MLD: vlanId(portId) is V1 but rcvd V2 from
nbr ipAddr
Explanation
Port has received a query with a MLD version that does not match the port
MLD version. This message is rated-limited to appear a maximum of once
every 10 hours.
Message Level
Warning
Message
Latched low RX Power | TX Power | TX Bias Current
| Supply Voltage | Temperature warning alarm |
warning, port port-number
Explanation
The optical transceiver on the given port has risen above or fallen below
the alarm or warning threshold.
Message Level
Warning
Message
list ACL-num denied ip-proto src-ip-addr ( src-
tcp / udp-port ) (Ethernet portnum mac-addr ) -
dst-ip-addr ( dst-tcp / udp-port ), 1 event(s)
Explanation
Indicates that an Access Control List (ACL) denied (dropped) packets.
The ACL-num indicates the ACL number. Numbers 1 - 99 indicate standard
ACLs. Numbers 100 - 199 indicate extended ACLs.
The ip-proto indicates the IP protocol of the denied packets.
The src-ip-addr is the source IP address of the denied packets.
Syslog messages
336
FastIron Ethernet Switch Administration Guide
53-1003625-01
Содержание FastIron
Страница 28: ...Displaying management VRF information 28 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 146: ...Displaying interface level IPv6 settings 146 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 162: ...Example 2 162 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 172: ...Clearing CDP information 172 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 216: ...Clearing cached LLDP neighbor information 216 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 228: ...FastIron Fiber optic Transceivers 228 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 284: ...show sysmon system sfm 284 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 296: ...Syslog messages for hardware errors 296 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 384: ...Displaying information for breakout ports 384 FastIron Ethernet Switch Administration Guide 53 1003625 01...