Notice that the static buffer contains two separate messages for fan failures. Each message of each
type has its own buffer. Thus, if you replace fan 1 but for some reason that fan also fails, the software
replaces the first message about the failure of fan 1 with the newer message. The software does not
overwrite the message for fan 2, unless the software sends a newer message for fan 2.
Clearing log entries
When you clear log entries, you can selectively clear the static or dynamic buffer, or you can clear both.
For example, to clear only the dynamic buffer, enter the following command at the Privileged EXEC
level.
device#clear logging dynamic-buffer
Syntax:
clear logging
[
dynamic-buffer
|
static-buffer
]
You can specify
dynamic-buffer
to clear the dynamic buffer or
static-buffer
to clear the static buffer. If
you do not specify a buffer, both buffers are cleared.
Time stamps
The contents of the time stamp differ depending on whether you have set the time and date on the
onboard system clock:
• If you have set the time and date on the onboard system clock, the date and time are shown in the
following format.
mm dd hh:mm:ss
where
•
‐
mm
- abbreviation for the name of the month
‐
dd
- day
‐
hh
- hours
‐
mm
- minutes
‐
ss
- seconds
For example, "Oct 15 17:38:03" means October 15 at 5:38 PM and 3 seconds.
• If you have not set the time and date on the onboard system clock, the time stamp shows the amount
of time that has passed since the device was booted, in the following format.
num d num h num m num s
where
•
‐
num d
- day
‐
num h
- hours
‐
num m
- minutes
‐
num s
- seconds
For example, "188d1h01m00s" means the device had been running for 188 days, 11 hours, one minute,
and zero seconds when the Syslog entry with this time stamp was generated.
Example of Syslog messages on a device with the onboard clock set
The example shows the format of messages on a device where the onboard system clock has been set.
Each time stamp shows the month, the day, and the time of the system clock when the message was
Clearing log entries
FastIron Ethernet Switch Administration Guide
289
53-1003625-01
Содержание FastIron
Страница 28: ...Displaying management VRF information 28 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 146: ...Displaying interface level IPv6 settings 146 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 162: ...Example 2 162 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 172: ...Clearing CDP information 172 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 216: ...Clearing cached LLDP neighbor information 216 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 228: ...FastIron Fiber optic Transceivers 228 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 284: ...show sysmon system sfm 284 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 296: ...Syslog messages for hardware errors 296 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 384: ...Displaying information for breakout ports 384 FastIron Ethernet Switch Administration Guide 53 1003625 01...