dynamic route to be chosen over a static route, you can configure the static route with a higher
administrative distance than the dynamic route.
Configuring a static route in a non-default VRF or User VRF
To configure a static IPv6 route for a destination network with the prefix 2001:DB8::0/32, a next-hop
gateway with the global address 2001:DB8:0:ee44::1, in the non-default VRF named "blue", enter the
following at the general configuration prompt.
device(config)# ipv6 route vrf blue 2001:DB8::0/32 2001:DB8:0:ee44::1
Syntax:
[no] ipv6 route
vrf
vrf-name
dest-ipv6-prefix/prefix-length
next-hop-ipv6-address
The
dest-ip-addr
is the route’s destination. The
dest-mask
is the network mask for the route’s
destination IPv6 address.
The
vrf-name
is the name of the VRF that contains the next-hop router (gateway) for the route.
The
next-hop-ip-addr
is the IPv6 address of the next-hop router (gateway) for the route.
NOTE
The
vrf
needs to be a valid VRF to be used in this command.
IPv6 over IPv4 tunnels
NOTE
This feature is supported only with the IPv6 Layer 3 license on FSX devices and the full Layer 3 image
on other devices.
To enable communication between isolated IPv6 domains using the IPv4 infrastructure, you can
manually configure IPv6 over IPv4 tunnels that provide static point-point connectivity.
As shown in the following illustration, these tunnels encapsulate an IPv6 packet within an IPv4 packet.
FIGURE 2
IPv6 over an IPv4 tunnel
In general, a manually configured tunnel establishes a permanent link between switches in IPv6
domains. A manually configured tunnel has explicitly configured IPv4 addresses for the tunnel source
and destination.
Configuring a static route in a non-default VRF or User VRF
FastIron Ethernet Switch Administration Guide
141
53-1003625-01
Содержание FastIron
Страница 28: ...Displaying management VRF information 28 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 146: ...Displaying interface level IPv6 settings 146 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 162: ...Example 2 162 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 172: ...Clearing CDP information 172 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 216: ...Clearing cached LLDP neighbor information 216 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 228: ...FastIron Fiber optic Transceivers 228 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 284: ...show sysmon system sfm 284 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 296: ...Syslog messages for hardware errors 296 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 384: ...Displaying information for breakout ports 384 FastIron Ethernet Switch Administration Guide 53 1003625 01...