Field definitions for the show inline power detail command (Continued)
TABLE 45
Column
Definition
Power Budget
The power budget allocated to the slot. The default value is 65535 watts. Any other
value indicates that the power budget was configured using the CLI command
inline power budget
.
Total
The totals for all of the fields in the
Cumulative Port Power Data
report.
Inline power on PoE LAG ports
The inline power on Power over Ethernet (PoE) LAG ports feature allows you to enable inline power on
PoE LAG ports with the introduction of a new
inline power ethernet
command, available in global
configuration mode.
Without the
inline power ethernet
command, you cannot enable inline power on any secondary LAG
ports because the interface configuration mode is not available for LAG secondary ports to run the
inline power
command.
You can configure inline power in interface configuration mode on a port that is not a member of a LAG.
If that port then becomes part of a LAG, you can use the
inline power ethernet
command to configure
inline power parameters on any other port in that LAG.
LAG operational changes can affect the PoE power state unless the
decouple-datalink
keyword is
used as a command option when configuring inline power on the LAG ports. For more information, refer
to “Decouple the PoE and datalink operations on PoE ports.”
After configuring inline power on PoE ports, you can verify the configuration using the
show running-
config
command. If you have configured inline power on a regular PoE port in either global
configuration or interface configuration mode, the inline power configuration commands display under
the interface configuration level. If a regular PoE port becomes a PoE LAG port, or a PoE LAG port is
configured under global configuration mode, the inline power configuration commands display under the
global configuration level. If a LAG is removed, the inline power configuration commands for all ports
display under the interface configuration level.
WARNING
If you downgrade to a release earlier than 08.0.01, there is no backwards compatibility for the
inline
power ethernet
command or the
decouple-datalink
keyword.
Restriction
If you want to keep decoupling in place on a PoE port when you configure the
inline power
ethernet
command to change its other parameters, for example, priority, you must also configure the
decouple-
datalink
keyword.
Inline power on PoE LAG ports
FastIron Ethernet Switch Administration Guide
371
53-1003625-01
Содержание FastIron
Страница 28: ...Displaying management VRF information 28 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 146: ...Displaying interface level IPv6 settings 146 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 162: ...Example 2 162 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 172: ...Clearing CDP information 172 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 216: ...Clearing cached LLDP neighbor information 216 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 228: ...FastIron Fiber optic Transceivers 228 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 284: ...show sysmon system sfm 284 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 296: ...Syslog messages for hardware errors 296 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 384: ...Displaying information for breakout ports 384 FastIron Ethernet Switch Administration Guide 53 1003625 01...