hitless-supported services and protocols. Unlike a switchover, a failover generally happens without
warning.
Hitless Operating System (OS) Upgrade
- An operating system upgrade and controlled switchover
without any packet loss to the services and protocols that are supported by Hitless management. The
services and protocols supported by Hitless management are listed in this section. Hitless failover and
hitless switchover are disabled by default.
Benefits of hitless management
The benefits of Hitless management include the following:
• The standby management module (the module that takes over the active role) and all interface
modules in the chassis are not reset
• Existing data traffic flows continue uninterrupted with no traffic loss
• Port link states remain UP for the duration of the hitless management event
• System configurations applied through Console/SNMP/HTTP interfaces remain intact
• Hitless switchover can be used by a system administrator, for example, to perform maintenance on a
management module that has been functioning as the active management module. Some
advantages of a hitless switchover over a hitless software reload are:
‐
A manual switchover is quicker, since the standby module does not have to reboot.
‐
Switched traffic through the Ethernet interfaces on the standby management module is not
interrupted.
NOTE
All traffic going through Ethernet interfaces (if present) on the management modules will be interrupted
during a hitless OS upgrade. This is because both management modules must be reloaded with the
new image. This applies to hitless OS upgrade only. It does not apply to hitless switchover or failover,
which does not interrupt traffic going through Ethernet interfaces on the standby management module
(the module that takes over the active role).
Supported protocols and services for hitless management events
The following table lists the services and protocols that are supported by Hitless management, and also
highlights the impact of
Hitless management events
(switchover, failover, and OS upgrade) to the
system’s major functions. The services and protocols that are not listed may be disrupted, but will
resume normal operation once the new active management module is back up and running.
Benefits of hitless management
FastIron Ethernet Switch Administration Guide
123
53-1003625-01
Содержание FastIron
Страница 28: ...Displaying management VRF information 28 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 146: ...Displaying interface level IPv6 settings 146 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 162: ...Example 2 162 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 172: ...Clearing CDP information 172 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 216: ...Clearing cached LLDP neighbor information 216 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 228: ...FastIron Fiber optic Transceivers 228 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 284: ...show sysmon system sfm 284 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 296: ...Syslog messages for hardware errors 296 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 384: ...Displaying information for breakout ports 384 FastIron Ethernet Switch Administration Guide 53 1003625 01...