Field definitions for the show inline power pd command (Continued)
TABLE 44
Column
Definition
Total PD Power
Switched to PSE
Total PD power switched to PSE. It is either 0 or the total available power.
Port
The port number of the PD port.
Oper State
The operational state of the PD port. This value can be one of the following:
• On - The PD port is linked to a PSE port and is consuming power.
• Off - The PD port is not linked to a PSE port and is not consuming power.
Oper Mode
The operational mode of the PD port. This value is meaningful if Oper State is On. This
value can be one of the following:
• 802.3af - The PD port is operating in the AF mode.
• 802.3at - The PD port is operating in the AT mode.
• n/a - The PD port is not operational.
Fault/Error
Shows the error or fault conditions affecting the PD port. This value can be one of the
following:
• An error or fault code is displayed.
• n/a - No error or fault condition on the PD port.
Displaying detailed information about PoE power supplies
The
show inline power detail
command displays detailed operational information about the PoE
power supplies in FastIron PoE switches. The command output differs on FCX POE+ switches
compared to FSX Series and ICX switches.
The following is an example of the
show inline power detail
command output on an FCX POE+
switch.
device# show inline power detail
Power Supply Data On stack 1:
++++++++++++++++++
Power Supply #1:
Max Curr: 7.5 Amps
Voltage: 54.0 Volts
Capacity: 410 Watts
POE Details Info. On Stack 1 :
General PoE Data:
+++++++++++++++++
Firmware
Version
--------
02.1.0
Cumulative Port State Data:
+++++++++++++++++++++++++++
#Ports #Ports #Ports #Ports #Ports #Ports #Ports
Admin-On Admin-Off Oper-On Oper-Off Off-Denied Off-No-PD Off-Fault
-------------------------------------------------------------------------
45 3 0 48 0 45 0
Cumulative Port Power Data:
+++++++++++++++++++++++++++
#Ports #Ports #Ports Power Power
Pri: 1 Pri: 2 Pri: 3 Consumption Allocation
-----------------------------------------------
0 0 45 0.0 W 0.0 W
Power Supply Data On stack 2:
Displaying detailed information about PoE power supplies
364
FastIron Ethernet Switch Administration Guide
53-1003625-01
Содержание FastIron
Страница 28: ...Displaying management VRF information 28 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 146: ...Displaying interface level IPv6 settings 146 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 162: ...Example 2 162 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 172: ...Clearing CDP information 172 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 216: ...Clearing cached LLDP neighbor information 216 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 228: ...FastIron Fiber optic Transceivers 228 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 284: ...show sysmon system sfm 284 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 296: ...Syslog messages for hardware errors 296 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 384: ...Displaying information for breakout ports 384 FastIron Ethernet Switch Administration Guide 53 1003625 01...