SYSTEM INSTALLATION MANUAL
89000016
(2)
The FT -9000 ramp tester kit part number can be ordered as an optionaI item using the part
number specified in Table 1009.
Table 1009. FT-9000 RAMP Tester Kit
Part Number
Quantity
Description
87579-00
1
FT-9000 ADS-B RAMP Tester Kit
6.
Equipment Mounting
A.
KGX Control Panel Mounting
(1)
The KGX control panel must be mounted rigidly in the aircraft panel. The KGX control panel
can be mounted in the ultra-compact mounting hole or in a conventional 2.25 inch (57 mm)
instrument cut-out. Refer to Figure 1003 and Figure 1004.
(2)
The following installation procedure must be followed, remembering to supply adequate space
for installation of cables and connectors.
(a)
Select a position in the panel that is not too close to any high external heat source (the
KGX control panel is not a significant heat source itself).
(b)
Avoid sharp bends and placing the cables too near to the aircraft control cables.
(c)
If using a 2.25 inch (57 mm) instrument cut-out, first clip the two mounting adapters to the
KGX control panel. It must then be mounted using the four long screws provided.
(d)
If using the ultra-compact cutout, you do not need the mounting adapters. The KGX
control panel must be mounted using the four short screws provided.
(e)
If alternate screws are required, please note that the mounting thread in each case is 4-40.
(3)
Refer to Figure 1001 for the KGX control panel dimensions.
EFFECTIVITY
ALL
Page 1005
22 Dec 2016
© Honeywell International Inc. Do not copy without express permission of Honeywell.