SYSTEM INSTALLATION MANUAL
89000016
Table 5001. KGX UAT DO-160G Qualification (Cont)
Condition
Paragraph
Category
Spec.
Audio frequency conducted susceptibility -
Power inputs
18
Z
-
Induced signal susceptibility
19
AC
-
Radio frequency susceptibility
20
TT
-
Emission of radio frequency energy
21
B
-
Lightning, induced transient susceptibility
22
A2J3L3 (shielded)
A2H3L3
(unshielded)
-
Lightning direct effects
23
NA
-
Icing
24
NA
-
Electrostatic discharge
25
A
-
Fire, flammability
26
C
-
2.
KGX Control Panel DO-160 Qualification
A.
General
(1)
Refer to Table 5002 for the KGX Control Panel DO-160 qualification.
Table 5002. KGX Control Panel DO-160F Qualification
Condition
Paragraph
Category
Spec.
Temperature and altitude
4
C4/C4/A4
-
Ground survival low temperature
4.5.1
C4
67 F ( 55 C)
Short-time operating low temperature
4.5.1
C4
13 F ( 25 C)
Operating low temperature
4.5.2
C4
4 F ( 20 C)
Short-time operating high temperature
4.5.3
C4
+158 F (+70 C)
Ground survival high temperature
4.5.3
C4
+185 F (+85 C)
Operating high temperature
4.5.4
C4
+131 F (+55 C)
Loss of cooling
4.5.5
NA
-
Altitude
4.6
D
+35,000 feet (+10,668 m)
Decompression
4.6.2
A
+50,000 feet (+15,240 m)
Overpressure
4.6.3
A
15,000 feet ( 4,572 m)
Temperature variation
5
A
-
Humidity
6
A
-
EFFECTIVITY
ALL
Page 5002
22 Dec 2016
© Honeywell International Inc. Do not copy without express permission of Honeywell.