SYSTEM INSTALLATION MANUAL
89000016
RTCA DO-160 ENVIRONMENTAL QUALIFICATION
1.
KGX UAT DO-160 Qualification
A.
General
(1)
Refer to Table 5001 for the KGX UAT DO-160 qualification.
Table 5001. KGX UAT DO-160G Qualification
Condition
Paragraph
Category
Spec.
Temperature and altitude
4
C4/D/A
40 to +158 F ( 40 to
+70 C)
Operating low temperature
4.5.2
C4
40 F ( 40 C)
Operating high temperature
4.5.4
C4
+158 F (+70 C)
Short-time operating low temperature
4.5.1
C4
40 F ( 40 C)
Short-time operating high temperature
4.5.3
C4
+158 F (+70 C)
Ground survival low temperature
4.5.1
C4
67 F ( 55 C)
Ground survival high temperature
4.5.3
C4
+185 F (+85 C)
Loss of cooling
4.5.5
NA
-
Altitude
4.6
D
+50,000 feet (+15,240 m)
Decompression
4.6.2
A
+50,000 feet (+15,240 m)
Overpressure
4.6.3
A
15,000 feet (-4,572 m)
Temperature variation
5
B
-
Humidity
6
A
-
Shock/crash safety
7
B
-
Vibration
8
S (Zone 1, Curve
C) and U2
-
Explosive atmosphere
9
NA
-
Waterproofness
10
NA
-
Fluids susceptibility
11
NA
-
Sand and dust
12
NA
-
Fungus resistance
13
NA
-
Salt fog
14
S
-
Magnetic effect
15
Z
-
Power input
16
BB
-
Voltage spike
17
A
-
EFFECTIVITY
ALL
Page 5001
22 Dec 2016
© Honeywell International Inc. Do not copy without express permission of Honeywell.