SYSTEM INSTALLATION MANUAL
89000016
NOTE:
X = Channel number.
(a)
The following options are offered for selecting the serial input baud rate for each channel
data type:
• 4800
• 9600
• 19200
• 38400
• 57600
• 115200
• 230400.
(b)
The display screen is as shown in Figure 3056 with one of the options from above.
(c)
Rotate the CODE knob either clockwise or counterclockwise to display the options above
and select the correct serial input speed. Once selected, press the ENT key to confirm
your selection and move to the next configuration item in the configuration mode.
Figure 3056. (Sheet 1 of 1) Serial IN Channel X Line Speed Display
(10) Serial OUT Channel X Data Type
NOTE:
X = Channel number.
(a)
The KGX can transmit data through two serial channels. The following options are offered
for selecting serial output type for each individual channel of the KGX.
NOTE:
Refer to the GENERAL INFORMATION section for details on selecting serial
output settings.
1
Channel 2:
• Not used
• Encoded altitude
• TIS/FIS
• ADS-B pass thru
• XPDR monitor
• MX-20.
NOTE:
XPDR monitor is only used in conjunction with FTM-190C, external
Transponder Monitor.
2
Channel 5:
• Not used
• TIS/FIS
• ADS-B pass thru
• MX-20.
EFFECTIVITY
ALL
Page 3047
22 Dec 2016
© Honeywell International Inc. Do not copy without express permission of Honeywell.