Table 4002. UAT Status LED/Discrete Fault Indications (Cont)
Problem Reported
Reported By
RF transmission power too low
PBIT
GWSS not communicating or reporting fault
PBIT
RF transmit power supply low
PBIT
Internal temperature too high
PBIT
RF transmit reverse power too high
PBIT
Nominal message rate not once for each second
PBIT
Broadcast monitor failure - All message types not transmitted
PBIT
Nominal message rate not once for each second
PBIT
Internal power supply failure
PBIT
UART serial channel loopback test failure
POST
ARINC 429 channel loopback test failure (KGX)
POST
General processing/interface hardware failure
POST
Transceiver hardware check failure
POST
3.
System Messages
A.
General
(1)
If the KGX detects a malfunction, the KGX control panel displays the MSG icon in the center of
the LCD. Depending on the nature of the malfunction, the KGX can possibly not be transmitting
ADS-B messages. To view the system messages on the Warning page, push the FN button
four times and WARNING is displayed top center along with a brief description of the fault. The
Warning page is only available when the MSG icon is present.
(2)
When the Warning page is displayed, the KGX control panel continually requests the active
system messages. The MSG icon will remain as shown as long as system messages are
still present.
(3)
The MSG icon is only present when a malfunction is present. A log of system messages
can be accessed using the MPI.
(4)
Refer to Table 4003 for the KGX control panel system messages.
Table 4003. KGX Control Panel System Messages
System Message
Description
Synth Unlock
Transceiver diagnostic - Timing fault
Tx Fault
UAT transceiver fault
Tx Power Low
UAT transceiver power low during transmit
Tx PSU High
UAT transceiver power supply output too high
Tx PSU Low
UAT transceiver power supply output too low
Squitter Fail
System diagnostic