SYSTEM INSTALLATION MANUAL
89000016
(2)
Paragraph 3.B. thru Paragraph 3.C. describe the system installation configuration details
necessary for configuring the KGX installation. Installers must review the information in these
sections to make sure of the correct system configuration. It is important to carefully review
Paragraph 3.C. to make sure of the correct system configuration of the serial and ARINC ports,
regardless of using the MPI or KGX control panel for configuration.
(3)
For reference, the configuration sections are organized as follows:
• Installation Setup and Configuration - General Configuration Details
• Configuration Item Summary - List of all Configuration Item
• Serial and ARINC Port Configuration Details - General Port Details
• Configuration and Setup Using MPI
• Configuration and Setup Using the KGX control panel.
B.
Configuration Item Summary
(1)
Refer to Table 3001 for the Serial and ARINC Port Configuration Settings.
(2)
Refer to Table 3002 for the ADS-B transmit Configuration Settings.
(3)
Refer to Table 3003 for the display output Configuration Settings.
(4)
The setting column of the following tables can be used to document the system installation
settings.
Table 3001. Serial and ARINC Port Configuration Settings
Configuration Item
Function/BAUD
Default
Setting
IN Function
Internal GPS
Serial Port 1 Configuration:
BAUD
19200
IN Function
UNUSED
OUT Function
UNUSED
Serial Port 2 Configuration:
BAUD
9600
IN Function
TMAP
OUT Function
TMAP
Serial Port 3 Configuration:
1
BAUD
38400
IN Function
UNUSED
Serial Port 4 Configuration:
BAUD
9600
IN Function
MAINT
OUT Function
MAINT
Serial Port 5 Configuration:
BAUD
115200
IN Function
UNUSED
OUT Function
UNUSED
BAUD
9600
Serial Port 6 Configuration:
Interface
RS-422
EFFECTIVITY
ALL
Page 3005
22 Dec 2016
© Honeywell International Inc. Do not copy without express permission of Honeywell.