SYSTEM INSTALLATION MANUAL
89000016
(c)
Rotate the CODE knob either clockwise or counterclockwise to display the options above
and select the correct ARINC input interface speed. Once selected, press the ENT key to
confirm your selection and move to the next configuration item in the configuration mode.
Figure 3060. (Sheet 1 of 1) ARINC IN Channel X Interface Speed Display
(14) ARINC OUT Chan 1 Data Type
(a)
The KGX can transmit data through an ARINC 429 output channel. The following options
are offered for selecting ARINC 429 output type:
• Not used
• GPS
• Traffic.
NOTE:
Refer to Paragraph 3.C. Step (5) in the CONFIGURATION, CALIBRATION,
AND CHECKOUT section for information on selecting ARINC output settings.
(b)
The display screen is as shown in Figure 3061 with one of the options from above.
(c)
Rotate the CODE knob either clockwise or counterclockwise to display the options above
and select the correct ARINC output type. Once selected, press the ENT key to confirm
your selection and move to the next configuration item in the configuration mode.
NOTE:
If “not used” is selected then the ARINC output line speed configuration mode
is not displayed and the next configuration mode item is displayed.
Figure 3061. (Sheet 1 of 1) ARINC OUT Chan 1 Data Type Display
(15) ARINC OUT Chan 1 Interface Speed
(a)
The following options are offered for selecting the ARINC output interface speed:
• Low
• High.
(b)
The display screen is as shown in Figure 3062 with one of the options from above.
(c)
Rotate the CODE knob either clockwise or counterclockwise to display the options above
and select the correct ARINC output interface speed. Once selected, press the ENT key to
confirm your selection and move to the next configuration item in the configuration mode.
EFFECTIVITY
ALL
Page 3050
22 Dec 2016
© Honeywell International Inc. Do not copy without express permission of Honeywell.