80-0000010B OM
73
On tractors “BELARUS-80.1/82.1/820” signal for engine speed calculation is a al-
ternator phase winding (terminal “W”). Rotation range indication is from 0 to 3500 (min
-1
).
c) 3 (figure 2.26.1) – PTO speed indicator displays on light indicator power take-off
shaft speed.
PTO speed indicator operates from frequency signal received by recalculation from
the signal of alternator phase winding with the help of entered factor “KV2” value (see be-
low) other than “0”, in this case factor ZV value equal to “0” shall be entered (see below).
With MIU turned on (see below description of device operation check) and engine
started (signal transmission from alternator phase winding) scales symbols “540” and
“1000” light up simultaneously.
Indication of PTO scale section (taking into account entered factor “KV2” value) takes
place when calculated PTO speed reaches 750 min
-1
.
Indication of lower PTO scale section (taking into account factor “KV2”) takes place
when engine speed reaches 1400-1500 (min
-1
) and higher.
Depending on the PTO operation speed mode on (540 or 1000) illuminated scale
sections define PTO speed values in accordance with indicated table 2.26.1.
Liquid crystal display mode 10 MI (2.26.1) (see below description of MI operation)
“Revolutions of PTO” is inactive in this mode.
Table 2.26.1
“540”
“1000”
Location of section
on the scale
650
1150
3.1
580
1050
3.2
500
950
3.3
420
850
3.4
320
750
3.5
d) 10 (figure 2.26.1) – multifunctional indicator (MI), is a liquid crystal display, simul-
taneously displays information in two fields (see figure 2.26.2):
1 – digital symbol of gearbox switch position (digits from 0 to 6) or literal symbol of gear reduc-
ing unit switch position (letters L, M, H, N);
2 – current numerical value of one of tractor system parameters.
Figure 2.26.2 – MI information fields
In information field “1” (figure 2.26.2) letter “A” is displayed, because transmission con-
trol modules are not available.
In information field “2” (figure 2.26.2) the following parameters are displayed:
- total astronomical engine operating time;
- engine operating time for the chosen period;
- diagnostic of speed sensors operation performance;
Switching between indication modes “Total astronomical engine operating time”, “En-
gine operating time for the chosen period”, failure reports is carried out by button “Mode” of
control console 7 (figure 2.24.1). Operation algorithm description of “Diagnostic of speed sen-
sors operation performance” is given below.
Содержание 80.1 Series
Страница 1: ...BELARUS 80 1 82 1 820 80 0000010B OM OPERATION MANUAL 2015 ...
Страница 15: ...80 0000010B OM 15 Figure 1 1 3 Tractor BELARUS 820 ...
Страница 274: ...80 0000010B OM 274 ...
Страница 378: ...80 0000010B OM 378 Service bulletins ...
Страница 379: ......
Страница 380: ......
Страница 381: ......