Parameter
Parameter manual
b maXX
®
1000
Document no. 5.07004.03
43
4
P0310
This parameter allows the user to reset all parameters to the factory settings except the
fault records (
).
50 Hz:
and
are set to 50 Hz and
60 Hz:
and
are set to 60 Hz and
will be set to 230 V or 460 V
When
= 11, all parameters are read-only.
To write all parameter, set
P0311
This parameter displays the status of the last data set management command.
P0317
Number of write counts in EEPROM. This counter will be incremented at write access for
parameters (
,
,
,
,
,
,
,
, internal parameter 1, internal parameter 2) to EE-
PROM by Power OFF.
P0310
Parameter Reset
0 to 11
EE
Parameter reset
0
STOP
BM_u_ParameterReset
1:1
-
Value
Meaning
0
Parameter can be set and read
3 to 8
Reserved
9
Reset parameter to factory setting for 50 Hz motor
10
Reset parameter to factory setting for 60 Hz motor
11
Parameter are read only
P0311
Datensatzverwaltung Status
0 to 2
-
Data set status
0
A
BM_w_RecordStatus
1:1
-
Status
Meaning
0
No error
1
Write/read cycle in process
2
Error
P0317
Anzahl Schreibvorgänge EEPROM
1 to 65535
-
EEPROM write count
0
A
BM_u_EepromWriteCount
1:1
-
Содержание b maXX 1000
Страница 1: ...E 5 07004 03 b maXX 1000 Parameter manual ...
Страница 65: ...Parameter Parameter manual b maXX 1000 Document no 5 07004 03 65 of 208 4 Figure 18 Base block speed search ...
Страница 164: ...Parameter manual b maXX 1000 Document no 5 07004 03 Baumüller Nürnberg GmbH 164 of 208 A ...
Страница 208: ...Parameter manual b maXX 1000 Document no 5 07004 03 Baumüller Nürnberg GmbH 208 of 208 Notes ...
Страница 209: ......