Parameter
Parameter manual
b maXX
®
1000
Document no. 5.07004.03
83
4
For example:
If setting MI3, MI5 and MI6 to be ON,
should be set to
bit5 x 2
5
+ bit4 x 2
4
+ bit2 x 2
2
= 1 x 2
5
+ 1 x 2
4
+ 1 x 2
2
= 32 + 16 + 4 = 52 as shown in
the following.
Figure 29:
Internal terminal status 2
When extension card is installed, the number of the multi-function input terminals will in-
crease according to the extension card. The maximum number of the multi-function input
terminals is 12.
Figure 30:
Extension card 2