Parameter description
Parameter manual
b maXX
®
1000
Document no. 5.07004.03
Baumüller Nürnberg GmbH
30
4.3
P0113
Setting this parameter changes the response time for the torque compensation
P0114
While driving an asynchronous motor, increasing the load on the drive will cause on in-
crease slip and decrease in speed. This parameter may be used to compensate the slip
by increasing the output frequency. When the output current of the drive is bigger than
the motor no-load current
, the drive will adjust its output frequency according
to this parameter.
P0115
This parameter sets the upper limit of the compensation frequency (the percentage of
Example:
when
= 5 Hz and
= 150 %, the upper limit of the compensation fre-
quency is 5 Hz
⋅
150 % =
7.5 Hz. Therefore, for a 50 Hz motor, the max. output is 57.5 Hz.
P0113
Drehmomentanpassung Zeitkonstante
0.01 to 10.00 s
EE
Torque compensation time constant
0.10 s
STOP
BM_u_TorqueCompTimeConst
100:1
-
NOTE
Too long time constants give slow response, too short values can give unstable operation.
P0114
Motor Schlupfanpassung
0.00 to 10.00 %
EE
Motor slip compensation
0.00 %
ON
BM_u_MotorSlipComp
1:1
-
P0115
Motor Schlupfanpassung Grenze
0 to 250 %
EE
Motor slip compensation limit
200 %
STOP
BM_u_MotorSlipCompLimit
1:1
-
Содержание b maXX 1000
Страница 1: ...E 5 07004 03 b maXX 1000 Parameter manual ...
Страница 65: ...Parameter Parameter manual b maXX 1000 Document no 5 07004 03 65 of 208 4 Figure 18 Base block speed search ...
Страница 164: ...Parameter manual b maXX 1000 Document no 5 07004 03 Baumüller Nürnberg GmbH 164 of 208 A ...
Страница 208: ...Parameter manual b maXX 1000 Document no 5 07004 03 Baumüller Nürnberg GmbH 208 of 208 Notes ...
Страница 209: ......