Parameter
Parameter manual
b maXX
®
1000
Document no. 5.07004.03
67
4
P0908
This parameters determine the increase/decrease of the master frequency when operat-
ed via the multi-function inputs when
or 11 (down command).
P0909
The following parameter sets the source frequency for RS485 communication (first or
second frequency).
P0910
The following parameter sets the source frequency for CANopen communication (first or
second frequency).
P0908
Beschleunigung-/Verzögerungsfaktor für Up/Down
Betrieb mit konst. Geschwindigkeit
0.01 to 10.00 Hz/2 ms
EE
Accel/decel rate of change of UP/DOWN opera-
tion with constant speed
0.01 Hz / 2 ms
STOP
BM_u_AccelDecelRateUpDown
100:1
-
Value
Meaning
= 0
Increase/decrease the frequency by using UP/DOWN key. Only enabled, if the b maXX
®
1000 is in state operation.
= 1
Increase/decrease the frequency by acceleration/deceleration setting. Only enabled, if the
b maXX
®
1000 is in state operation.
= 2
Increase/decrease the frequency by
(constant speed).
= 3
Increase/decrease the frequency by
(pulse input).
P0909
Quellfrequenz der RS485 (Modbus) Kommunikati-
onsschnittstelle (U/min)
-32768 to 32767 rpm
-
Source frequency for RS485 (Modbus) commu-
nication interface (rpm)
0 rpm
ON
BM_u_SourceFrequencyRS485
1:1
-
P0910
Quellfrequenz der CANopen Kommunikations-
schnittstelle (U/min)
0 to 36000 rpm
-
Source frequency for CANopen communication
interface (rpm)
0 rpm
A
BM_u_SourceFrequencyCANopen
1:1
-
Содержание b maXX 1000
Страница 1: ...E 5 07004 03 b maXX 1000 Parameter manual ...
Страница 65: ...Parameter Parameter manual b maXX 1000 Document no 5 07004 03 65 of 208 4 Figure 18 Base block speed search ...
Страница 164: ...Parameter manual b maXX 1000 Document no 5 07004 03 Baumüller Nürnberg GmbH 164 of 208 A ...
Страница 208: ...Parameter manual b maXX 1000 Document no 5 07004 03 Baumüller Nürnberg GmbH 208 of 208 Notes ...
Страница 209: ......