![Baumuller b maXX 1000 Скачать руководство пользователя страница 13](http://html.mh-extra.com/html/baumuller/b-maxx-1000/b-maxx-1000_parameter-manual_2711401013.webp)
Drive Management
Parameter manual
b maXX
®
1000
Document no. 5.07004.03
13
3
m
State transitions of device control
0 Input of the status machine
NOT READY-TO-START
n
Event:
m
Switch on electronic power supply
m
Hardware reset or
m
Software reset
n
Action:
m
Initialization and self-test are started
1 NOT READY-TO-START
SWITCH-ON INHIBIT
n
Event:
m
Initialization and self-test are completed error-free
n
Action:
m
none
2 INHIBIT START
READY-TO-START
n
Event:
m
Command ’Shut down’
n
Condition:
m
Quickstop input = High
n
Action:
m
none
3 READY-TO-START
SWITCHED ON
n
Event:
m
Command ’switch on’
n
Condition:
m
Pulse enable = High
m
Supply voltage is present
n
Action:
m
none
4 SWITCHED ON
OPERATION ENABLED
n
Event:
m
Command ’operation enabled’
n
Condition:
m
Pulse enable input MI6 = High
n
Action:
m
Drive operation is enabled