Basic of CAN
Parameter manual
b maXX
®
1000
Document no. 5.07004.03
Baumüller Nürnberg GmbH
200
B.3
6041
hex
= P301 (status word)
6064
hex
= P2067 (encode increment)
6077
hex
= P2113 (torque actual value)
Notice for Transmit PDO mapping parameter
The total number of the mapped bytes at each transmit PDO may not exceed the CAN- message frame limit
of
8 bytes maximum
.
NAME
Index
Sub-
index
Data
type
Access
type
Default value
4. Transmit PDO Mapping
1A03
hex
00
hex
U8
RW
3
hex
01
hex
U16
RW
60410010
hex
02
hex
U32
RW
60640020
hex
03
hex
U16
RW
60770010
hex