Parameter description
Parameter manual
b maXX
®
1000
Document no. 5.07004.03
Baumüller Nürnberg GmbH
134
4.3
P1372
This parameter sets one of the skip frequencies. For further information see
P1373
This parameter sets one of the skip frequencies. For further information see
P1374
This parameter sets one of the skip frequencies. For further information see
P1375
This parameter sets one of the skip frequencies. It will cause the b maXX
®
1000 never to
remain within these frequency ranges with continuous frequency output.
These six parameters should be set as follows
≥
≥
≥
≥
≥
.
The frequency ranges may be overlapping.
Figure 61:
Skip frequencies
P1372
Ausblendfrequenz 2 obere Grenze
0.00 to 600.00 Hz
EE
Skip frequency 2 upper bound
0.00
STOP
BM_u_SkipFrequency2UpperBound
100:1
-
P1373
Ausblendfrequenz 2 untere Grenze
0.00 to 600.00 Hz
EE
Skip frequency 2 lower bound
0.00
STOP
BM_u_SkipFrequency2LowerBound
100:1
-
P1374
Ausblendfrequenz 3 obere Grenze
0.00 to 600.00 Hz
EE
Skip frequency 3 upper bound
0.00
STOP
BM_u_SkipFrequency3UpperBound
100:1
-
P1375
Ausblendfrequenz 4 untere Grenze
0.00 to 600.00 Hz
EE
Skip frequency 4 lower bound
0.00
STOP
BM_u_SkipFrequency4LowerBound
100:1
-
Содержание b maXX 1000
Страница 1: ...E 5 07004 03 b maXX 1000 Parameter manual ...
Страница 65: ...Parameter Parameter manual b maXX 1000 Document no 5 07004 03 65 of 208 4 Figure 18 Base block speed search ...
Страница 164: ...Parameter manual b maXX 1000 Document no 5 07004 03 Baumüller Nürnberg GmbH 164 of 208 A ...
Страница 208: ...Parameter manual b maXX 1000 Document no 5 07004 03 Baumüller Nürnberg GmbH 208 of 208 Notes ...
Страница 209: ......