Basic of CAN
Parameter manual
b maXX
®
1000
Document no. 5.07004.03
Baumüller Nürnberg GmbH
190
B.3
B.3.3
Objects for communication control
Identification
This object contains some information on the device.
Device type
Error Register
The object 1001
hex
contains a column of error-bits, which have the following meaning:
NAME
Index
Sub-index
Data
type
Access
type
Default value
Identity Object
1018
hex
00
hex
U8
RO
3
hex
Vendor ID
01
hex
U32
RO
reserved
Product Code
02
hex
U32
RO
reserved
Revision Number
03
hex
U32
RO
1
hex
NAME
Index
Sub-index
Data
type
Access
type
Default value
Device Type
1000
hex
00
hex
U32
RO
00010192
hex
NAME
Index
Sub-
index
Data
type
Access
type
Default Value
Error Register
1001
hex
00
hex
U8
RO
0
hex
Bit
Meaning
0
Error has occurred, general error
1
Current error
2
Power error
3
Temperature error
4
CAN communication error
5
Device profile-specific error
6
Not used
7
Manufacturer-specific error
Содержание b maXX 1000
Страница 1: ...E 5 07004 03 b maXX 1000 Parameter manual ...
Страница 65: ...Parameter Parameter manual b maXX 1000 Document no 5 07004 03 65 of 208 4 Figure 18 Base block speed search ...
Страница 164: ...Parameter manual b maXX 1000 Document no 5 07004 03 Baumüller Nürnberg GmbH 164 of 208 A ...
Страница 208: ...Parameter manual b maXX 1000 Document no 5 07004 03 Baumüller Nürnberg GmbH 208 of 208 Notes ...
Страница 209: ......