P0296
This parameter determines the reaction after a CAN-bus drop-out.
CANopen Index 6007
hex
for Node Guarding Error
P0297
This parameter determines the reaction after a power lost.
P0296
Fehlerreaktion CAN-Bus Signalausfall
0 to 255
EE
Reaction CAN-bus drop-out
0
STOP
BM_u_ReactionCANBusDropOut
1:1
-
Value
Meaning
255
No Reaction
0
Reaction according to
(error reaction code)
1
Pulse inhibit
2
Braking operation at the deceleration time
3
Braking operation at the quickstop time
4
Braking operation at the deceleration automatic time
6007
hex
0
hex
No Reaction
2
hex
Pulse inhibit, default value
3
hex
Quickstop
FFFF
hex
Reaction according to
P0297
Fehlerreaktion Spannungsausfall
0 to 255
EE
Error reaction power lost
0
STOP
BM_u_ErrorReactionPowerLost
1:1
-
Value
Meaning
-1
No Reaction
0
Pulse inhibit
1
Braking operation at the deceleration time
2
Braking operation at quickstop ramp
3
Braking operation at the deceleration automatic time
Содержание b maXX 1000
Страница 1: ...E 5 07004 03 b maXX 1000 Parameter manual ...
Страница 65: ...Parameter Parameter manual b maXX 1000 Document no 5 07004 03 65 of 208 4 Figure 18 Base block speed search ...
Страница 164: ...Parameter manual b maXX 1000 Document no 5 07004 03 Baumüller Nürnberg GmbH 164 of 208 A ...
Страница 208: ...Parameter manual b maXX 1000 Document no 5 07004 03 Baumüller Nürnberg GmbH 208 of 208 Notes ...
Страница 209: ......