![Baumuller b maXX 1000 Скачать руководство пользователя страница 60](http://html.mh-extra.com/html/baumuller/b-maxx-1000/b-maxx-1000_parameter-manual_2711401060.webp)
Parameter description
Parameter manual
b maXX
®
1000
Document no. 5.07004.03
Baumüller Nürnberg GmbH
60
4.3
P0866
This parameter is used to set the transmission speed between the communication card
and b maXX
®
1000.
P0867
This parameter defines the communication card protocol.
P0868
This parameter is set to how to react if transmission errors occur.
P0866
USB Kommunikationskarte Übertragungsgeschwin-
digkeit
0 to 4
EE
USB Communication card transmission speed
3
STOP
BM_u_USBCommCardTransSpeed
1:1
-
Value
Meaning
0
Baud rate 4800 bps (bits / second)
1
Baud rate 9600 bps
2
Baud rate 19200 bps
3
Baud rate 38400 bps
4
Baud rate 57600 bps
P0867
USB Kommunikationskarte Protokoll
0 to 5
EE
USB Communication card protocol
3
STOP
BM_u_USBCommCardProtocol
1:1
-
Value
Meaning
0
7, N, 2 (Modbus, ASCII)
1
7, E, 1 (Modbus, ASCII)
2
7, O, 1 (Modbus, ASCII)
3
8, N, 2 (Modbus, RTU)
4
8, E, 1 (Modbus, RTU)
5
8, O, 1 (Modbus, RTU)
P0868
USB Kommunikationskarte Übertragungsfehler
0 to 3
EE
USB Communication card transmission fault
treatment
0
ON
BM_u_USBCommCardTransFaultTreat
1:1
-
Value
Meaning
0
Warn and keep operating
1
Warn and RAMP to stop
2
Warn and COAST to stop
3
No warning and keep operating
Содержание b maXX 1000
Страница 1: ...E 5 07004 03 b maXX 1000 Parameter manual ...
Страница 65: ...Parameter Parameter manual b maXX 1000 Document no 5 07004 03 65 of 208 4 Figure 18 Base block speed search ...
Страница 164: ...Parameter manual b maXX 1000 Document no 5 07004 03 Baumüller Nürnberg GmbH 164 of 208 A ...
Страница 208: ...Parameter manual b maXX 1000 Document no 5 07004 03 Baumüller Nürnberg GmbH 208 of 208 Notes ...
Страница 209: ......