Basic of CAN
Parameter manual
b maXX
®
1000
Document no. 5.07004.03
Baumüller Nürnberg GmbH
180
B.3
n
Message frame structure
The COB ID of the request SDO results from 600h + address, from the response SDOs from 580
hex
+
address. The data field of the CAN data message frame (byte 8) for an SDO is organized into three parts,
a command specify CS (1 byte), a multiplexor M (3 bytes) and the actual user data area D0 - D3 (4 bytes).
SDO message frame:
The multiplexor M consists of the 16- bit index of an object and the related 8-bit-wide Sub-index. With seg-
mented message frames, the user data area is expanded by the 3 bytes of the multiplexor, whereby 7
bytes of user data per message frame can be transmitted. The command specified CS classifies the var-
ious SDO types.
n
Expedited transfer
Objects can be written or read, with their data comprised of a maximum of 4 bytes. Only two message
frames are required, a request and a response. All objects with the indices 1xxx
hex
, 2xxx
hex
and 6xxx
hex
can be addressed via expedited SDOs.
n
Writing objects
With the bmaxx1000 CANopen interface, expedited transfer is used to write objects. A client SDO (mas-
ter) transmits a write request to the bmaxx1000 CANopen slave interface. This slave carries out the re-
quest and acknowledges this with the response.
Initiate SDO download:
Figure 70:
Initiate SDO download protocol
COB ID
DLC
Byte 0
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7
600
hex
+
address
08
hex
CS
M
M
M
D0
D1
D2
D3
580
hex
+
address
08
hex
CS
M
M
M
D0
D1
D2
D3
Содержание b maXX 1000
Страница 1: ...E 5 07004 03 b maXX 1000 Parameter manual ...
Страница 65: ...Parameter Parameter manual b maXX 1000 Document no 5 07004 03 65 of 208 4 Figure 18 Base block speed search ...
Страница 164: ...Parameter manual b maXX 1000 Document no 5 07004 03 Baumüller Nürnberg GmbH 164 of 208 A ...
Страница 208: ...Parameter manual b maXX 1000 Document no 5 07004 03 Baumüller Nürnberg GmbH 208 of 208 Notes ...
Страница 209: ......