Parameter description
Parameter manual
b maXX
®
1000
Document no. 5.07004.03
Baumüller Nürnberg GmbH
88
4.3
For Example:
If
displays 52, it means MI1, MI2 and MI4 are active.
The display value
52 = 32 + 16 + 4 = 1 x 2
5
+ 1 x 2
4
+ 1 x 2
2
= bit 6 x 2
5
+ bit 5 x 2
4
+ bit 3 x 2
2
Figure 37:
Display status multi function input terminal 2
When extension card is installed, the number of the multi function input terminals will in-
crease according to the extension card. The maximum number of the multi-function input
terminals is 12.
Figure 38:
Display status multi function input terminal