Parameter description
Parameter manual
b maXX
®
1000
Document no. 5.07004.03
Baumüller Nürnberg GmbH
152
4.3
P2141
This parameter together with
(DIP switch multiplier) determines the CAN ad-
dress.
If
= 0,
default value is 21.
If
> 0,
=
(b maXX
®
1000 CAN address) is equal to the value of
, if the DIP
switch setting is 1.
= 0
> 0
P2141
Adresse-Einstellung für DIP-Schalter 1
0 to 127
EE
Address setting for DIP switch 1
21
STOP
BM_u_CANBaudrateWithSwitchOn1
1:1
-
DIP switch
DIP switch value
CAN address setting
Default value
1
2
3
1
0
0
1
21
0
1
0
2
22
1
1
0
3
23
0
0
1
4
24
1
0
1
5
25
0
1
1
6
26
1
1
1
7
27
DIP switch
DIP switch value
CAN address setting
Default value
1
2
3
1
0
0
1
1
0
1
0
2
2
1
1
0
3
3
0
0
1
4
4
1
0
1
5
5
0
1
1
6
6
1
1
1
7
7
Содержание b maXX 1000
Страница 1: ...E 5 07004 03 b maXX 1000 Parameter manual ...
Страница 65: ...Parameter Parameter manual b maXX 1000 Document no 5 07004 03 65 of 208 4 Figure 18 Base block speed search ...
Страница 164: ...Parameter manual b maXX 1000 Document no 5 07004 03 Baumüller Nürnberg GmbH 164 of 208 A ...
Страница 208: ...Parameter manual b maXX 1000 Document no 5 07004 03 Baumüller Nürnberg GmbH 208 of 208 Notes ...
Страница 209: ......