Parameter
Parameter manual
b maXX
®
1000
Document no. 5.07004.03
61
4
P0869
This parameter sets the over time detection of the communication card.
P0870
If the b maXX
®
1000 is controlled by CANopen communication, the communication ad-
dress for this drive must be set via this parameter. The communication address for each
b maXX
®
1000 must be different and unique.
b maXX
®
1000 CANopen address is set by parameter
only if CANopen hard-
ware address is set to 0 (switch 1 = off, switch 2 = off, switch 3 = off). Otherwise the hard-
ware setting is valid.
Figure 16:
DIP switch CANopen address
P0869
USB Kommunikationskarte Zeitfehler
0.0 to 120.0 s
EE
USB Communication card over time detection
0.0 s
ON
BM_u_USBCommCardOverTimeDetect
10:1
-
Value
Meaning
0.0
Disable
0.1 to 120.0 s
Over time detection enabled
P0870
CANopen Adresse
1 to 127
EE
CANopen address
1
STOP
BM_u_CANopenAddress
1:1
-
Value
Meaning
0
Disable CANopen
1 to 127
CANopen communication address