Parameter
Parameter manual
b maXX
®
1000
Document no. 5.07004.03
113
4
P1173
The deceleration time is used to determine the time required for the b maXX
®
1000 to
decelerate from the maximum output frequency
down to 0 Hz. The rate is linear
unless S-curve is „Enabled.“, see
.
Acceleration/deceleration time 1 or 2 can be switched by setting the external terminals
(MI3 to MI5 or MI7 to MI12)
or
to 7.
P1174
The quickstop ramp is effective in all quickstop procedures, not only in the speed-con-
trolled operation modes.
The quickstop time is used to determine the time required for the b maXX
®
1000 to ramp
from maximum output frequency
to 0 Hz.
For a correct functioning of brake operations at the quickstop- or deceleration the speed
controller must be sufficiently parameterized.
P1176
This parameter is used to ensure smooth acceleration and deceleration via S-curve. For
further information see
.
P1173
HLG Rücklaufzeit 1
0.1 to 600.0 s or
0.01 to 60.00 s
EE
RFG deceleration time 1
10.0 s
ON
BM_u_RFG1RampDownTime1
10:1 or 100:1
P1174
HLG Schnellhalt-Zeit
0.1 to 600.0 s or
0.01 to 60.00 s
EE
RFG quickstop time
10.0 s
ON
BM_u_RFG1StopTime
10:1 or 100:1
P1176
HLG S-Kurve Hochlaufzeit
0.1 to 600.0 s or
0.01 to 60.00 s
EE
RFG S-curve accel time
10.0 s
STOP
BM_u_RFG1SCurveAccelTime
10:1 or 100:1
Содержание b maXX 1000
Страница 1: ...E 5 07004 03 b maXX 1000 Parameter manual ...
Страница 65: ...Parameter Parameter manual b maXX 1000 Document no 5 07004 03 65 of 208 4 Figure 18 Base block speed search ...
Страница 164: ...Parameter manual b maXX 1000 Document no 5 07004 03 Baumüller Nürnberg GmbH 164 of 208 A ...
Страница 208: ...Parameter manual b maXX 1000 Document no 5 07004 03 Baumüller Nürnberg GmbH 208 of 208 Notes ...
Страница 209: ......