Parameter description
Parameter manual
b maXX
®
1000
Document no. 5.07004.03
Baumüller Nürnberg GmbH
130
4.3
P1359
This parameter selects the set point source of the PID controller of b maXX
®
1000.
P1360
Mode parameter for the freely programmable PID controller.
Note that the measured variable (feedback) controls the output frequency (Hz). Select in-
put terminal accordingly. Make sure this parameter setting does not conflict with the set-
ting for
(master frequency).
When
is set to 2 or 3, the set point (master frequency) for PID control is ob-
tained from the AVI or ACI/AVI2 external terminal (0 to +10 V
DC
or 4 to 20 mA) or from
multi-step speed. When
is set to 1, the set point is obtained from the keypad.
Negative feedback means: +target value - feedback
Positive feedback means: -target value + feedback.
P1359
PID Sollwert Auswahl
0 to 5
EE
PID set point selection
0
STOP
BM_u_SetPointSelection
1:1
-
Value
Meaning
0
Disable
1
Digital keypad UP/DOWN keys
2
AVI 0 to +10 V
DC
3
ACI 4 to 20 mA / AVI2 0 to +10V
DC
4
)
5
First to second frequency command
P1360
Eingang für PID Rückführung
0 to 3
EE
Input terminal for PID feedback
0
STOP
BM_u_InputPIDFeedback
1:1
-
Value
Meaning
0
Positive feedback 0 to +10 V
DC
AVI
1
Negative feedback 0 to +10 V
DC
AVI
2
Positive feedback 4 to 20 mA ACI or
Positive feedback 0 to +10 V
DC
AVI2
3
Negative feedback 4 to 20 mA ACI or
Negative feedback 0 to +10 V
DC
AVI2
Содержание b maXX 1000
Страница 1: ...E 5 07004 03 b maXX 1000 Parameter manual ...
Страница 65: ...Parameter Parameter manual b maXX 1000 Document no 5 07004 03 65 of 208 4 Figure 18 Base block speed search ...
Страница 164: ...Parameter manual b maXX 1000 Document no 5 07004 03 Baumüller Nürnberg GmbH 164 of 208 A ...
Страница 208: ...Parameter manual b maXX 1000 Document no 5 07004 03 Baumüller Nürnberg GmbH 208 of 208 Notes ...
Страница 209: ......