Figure 90: UCF setup, odd traverse, step 6
7. Center the long block over one of the center punch
marks on the side of the pipe. Align the long block so
that the pressure bolt is directly over the punch mark.
Fasten the block to the pipe by wrapping both chains
around the pipe and fastening the chains to the screw
hooks on the opposite side of the block.
Figure 91: UCF setup, odd traverse, step 7
8. Use the wing nuts to tighten the chains on the long block
until the block is tightly secured to the pipe.
IMPORTANT:
Make sure both chains are perpendicular to the bottom of
the block and are not twisted. If the chains are slanted, the
slack may cause the block to move.
Figure 92: UCF setup, odd traverse, step 8
9. Position the clamping fixture rails so that the fixed short
block is placed over the remaining center punch mark
on the opposite side of the pipe and the pressure bolt is
directly over the punch mark. Make sure the fixed short
block is not positioned on top of the chains of the long
block. The adjustable short block may be placed on
either side of the long block chains.
Figure 93: UCF setup, odd traverse, step 9
10. Wrap one short block chain around the pipe and fasten
the chain to the screw hook on the opposite side of the
block. Repeat this for the other short block.
Note:
Make sure the chains on both blocks are on the same
side of the fixture and are opposite the slide rail with the
ruler.
Figure 94: UCF setup, odd traverse, step 9
11. Use the screw hooks to tighten the chains on both the
fixed and adjustable short blocks until both blocks are
tightly secured to the pipe.
IMPORTANT:
Make sure the chains are perpendicular to the clamping
fixture and are not twisted. If the chains are slanted, the
slack may cause the fixture to move. Also, the transducer
spacing dimension may change after the transducers are
mounted.
78
Содержание Panametrics PanaFlow LC
Страница 1: ...PanaFlow LC User s manual 910 327 Rev A...
Страница 2: ...ii...
Страница 3: ...PanaFlow LC Panametrics liquid ultrasonic flowmeter User s manual 910 327 Rev A Sep 2019 iii...
Страница 4: ...no content intended for this page iv...
Страница 12: ...no content intended for this page xii...
Страница 44: ...Figure 58 Setting up pulse output 32...
Страница 49: ...Figure 60 Setting up alarm output 37...
Страница 80: ...no content intended for this page 68...
Страница 82: ...no content intended for this page 70...
Страница 86: ...no content intended for this page 74...
Страница 98: ...Table 30 Service Record Date Description of Service Performed By 86...
Страница 104: ...no content intended for this page 92...
Страница 106: ...no content intended for this page 94...
Страница 114: ...no content intended for this page 102...
Страница 138: ...no content intended for this page 126...
Страница 140: ...no content intended for this page 128...
Страница 145: ...no content intended for this page 133...