Standards
The equipment complies with the standards listed in the
following table:
Standards
IEC 60079-0:2011
EN 60079-0:2012 + A11:2013
IEC 60079-1:2014
EN 60079-1:2014
IEC 60529:2001
EN 60529:1991 + A1:2000
ATEX/IEC
Specific Conditions of Use:
1. 1he flameproof joints of the equipment are not intended
to be repaired. Consult the manufacturer if dimensional
information on the flameproof joints is necessary.
2. Follow the manufacturer’s instructions to reduce the
potential of an electrostatic charging hazard.
3. Consult the manufacturer for genuine replacement
flange fasteners. M10x35 hexagon socket cap screws of
ISO 12.9 DIN912 grade steel (zinc-plated) or better with a
minimum yield strength of 135,000 psi are acceptable
alternatives. M10x1.5, 365 mm Long, Zinc Plated, ISO 12.9
DIN912, 17-4 H1025 or better with minimum yield strength
of 145 KSI.
4. Consult the manufacturer for genuine replacement
enclosure/adapter fasteners.
5. Care should be taken to avoid creating an ignition
hazard due to impact or friction on the titanium
transducers which form part of the flameproof
enclosure.
6. The electronics enclosure is rated for an ambient
temperature range of -40°C to +60°C. The remote
mount junction box and flow body is rated for an
ambient temperature range of -40°C to +60°C.
7. The equipment temperature class is dependent on the
maximum process temperature and is according to the
following table:
Maximum Process
Temperature
Temperature Class
85°C
T6
100°C
T5
135°C
T4
150°C
150°C
US/CANADA
Specific Conditions of Use:
1. The electronics enclosure is rated for an ambient
temperature range of -40°C to +60°C. The remote
mount junction box and flow body is rated for an
ambient temperature range of -40°C to +60°C.
2. The equipment temperature class is dependent on
the maximum process temperature and mounting
configuration according to the following table
Maximum Process
Temperature
Temperature Class
85°C
T6
100°C
T5
120°C
T4A
135°C
T4
150°C
T3C
130
Содержание Panametrics PanaFlow LC
Страница 1: ...PanaFlow LC User s manual 910 327 Rev A...
Страница 2: ...ii...
Страница 3: ...PanaFlow LC Panametrics liquid ultrasonic flowmeter User s manual 910 327 Rev A Sep 2019 iii...
Страница 4: ...no content intended for this page iv...
Страница 12: ...no content intended for this page xii...
Страница 44: ...Figure 58 Setting up pulse output 32...
Страница 49: ...Figure 60 Setting up alarm output 37...
Страница 80: ...no content intended for this page 68...
Страница 82: ...no content intended for this page 70...
Страница 86: ...no content intended for this page 74...
Страница 98: ...Table 30 Service Record Date Description of Service Performed By 86...
Страница 104: ...no content intended for this page 92...
Страница 106: ...no content intended for this page 94...
Страница 114: ...no content intended for this page 102...
Страница 138: ...no content intended for this page 126...
Страница 140: ...no content intended for this page 128...
Страница 145: ...no content intended for this page 133...