3.5.3b Setting up frequency output
To program a Frequency Output, use steps as in section
“Log-in and Primary Pages” to navigate to the Input/Output
settings page:
1. In Meter Menu highlight [Digital Output (Std)] and press
[ENTER]. Then highlight [Frequency] option and press
[ENTER].
2. Setup the [Measurement], [Base Value], [Full Value], [Full
Frequency] and [Error Handling] options to suit your
needs. The Figure 59 below, shows the available options.
Also refer to the Table 9 below to understand each
option.
For measurement options available on Frequency Output
refer to Table 8.
Table 8: Measurement options for frequency output
Measurement
Channel
Measurement Options for Frequency
Output
Composite
Velocity, Actual Volumetric, Standard
Volumetric, Mass Flow, Average
Volumetric Flow Rate, Sound speed,
Reynolds #
Channel x
Velocity, Actual Volumetric, Standard
Volumetric, Mass Flow, Average
Volumetric Flow rate, Sound speed,
Standard Deviation of Gain, Gain and SNR
Table 9: Frequency output options
Option
Functional Description
Measurement Choose the channel and Measurement
to output
Base Value
Enter measurement value that should
correspond to the min. value of the
frequency range
Full Value
Enter measurement value that should
correspond to the max. value of the
frequency range
Fspan
Enter the highest value of the Frequency
range you want to output
Error Handling
Choose the Frequency output response
during an error condition: Low, High, Hold,
or Other Value. During a meter error, the
chosen Error Handling value will be sent
to the Frequency Output.
33
Содержание Panametrics PanaFlow LC
Страница 1: ...PanaFlow LC User s manual 910 327 Rev A...
Страница 2: ...ii...
Страница 3: ...PanaFlow LC Panametrics liquid ultrasonic flowmeter User s manual 910 327 Rev A Sep 2019 iii...
Страница 4: ...no content intended for this page iv...
Страница 12: ...no content intended for this page xii...
Страница 44: ...Figure 58 Setting up pulse output 32...
Страница 49: ...Figure 60 Setting up alarm output 37...
Страница 80: ...no content intended for this page 68...
Страница 82: ...no content intended for this page 70...
Страница 86: ...no content intended for this page 74...
Страница 98: ...Table 30 Service Record Date Description of Service Performed By 86...
Страница 104: ...no content intended for this page 92...
Страница 106: ...no content intended for this page 94...
Страница 114: ...no content intended for this page 102...
Страница 138: ...no content intended for this page 126...
Страница 140: ...no content intended for this page 128...
Страница 145: ...no content intended for this page 133...