Table 40: Setup Restart (cont'd.)
Name
Location
Description
Restart Delay
Trigger Info Screen
Every Stop trigger has a Restart
Delay. By default, the Restart
Delay is the Global Restart
Delay designated by the G in the
parameter value.
Change the restart value as
required by the application. When
the restart value is changed, the
user will be asked if the global
value should also be changed
or just the restart delay for this
trigger.
Set a
trigger’s Restart Delay to 0
to use the Global Restart Timer.
StrtCounterRst
Home Screen ->
Settings ->
Menu ->
Other Initial Setup ->
General Restart Params
Restart Counter Clear Time.
After the drive has run for the
StrtCounterRst time, all
triggers’
restart counts are reset to 0.
Default value is 60 minutes.
ProgRstDelay
Home Screen ->
Settings ->
Menu ->
Other Initial Setup ->
General Restart Params
Progressive Restart Delay Time.
This time is added to a
trigger’s
restart delay each time the fault
is repeated.
Default value is 0 minutes.
Содержание Apollo 3
Страница 1: ...Copyright 2020 Baker Hughes Company All rights reserved Page 1 of 277...
Страница 46: ...Copyright 2020 Baker Hughes Company All rights reserved Page 46 of 277 Figure 20 Backspin Probes Drawing 2...
Страница 139: ...Copyright 2020 Baker Hughes Company All rights reserved Page 139 of 277 Figure 116 Murphy Switch Trigger Example 1...
Страница 266: ...Copyright 2020 Baker Hughes Company All rights reserved Page 266 of 277 Figure 227 USB Menu...
Страница 267: ......
Страница 276: ......
Страница 277: ...Index 129112 28 197705 28 197349 28 800638 28 197350 28 810280 28 197351 29...