5.11
PLC Analog Control
The PLC Analog Control wizard allows an external device to control motor speed with an analog signal
and optionally control motor start/stop using a digital input. Execute the PLC Analog Control wizard to put
Apollo into this
“dumbed down” mode.
To execute the wizard, from the Home Screen select:
Settings -> Menu -> Other Initial Setup -> Next Page -> Next Page -> Configuration Wizards -> PLC Analog
Control. Note: If you just need start/stop control
and don’t need analog speed control, select the 2-wire
RunStop wizard.
Follow the on-screen directions.
Information needed by the PLC Analog Control wizard:
• Analog Input to use for Speed Control:
– Options are V7 Analog 1, V7 Analog 2, EIO Analog Option 1, EIO Analog Option 2.
• Analog Input Offset (desired pump speed when input is 0V/4mA ).
• Analog Input Span (desired pump speed range,pump speed when input is 10V/20mA minus pump speed
when input is 0V/4mA. For example, (with a 4-20mA input) if the desired pump speed at 4mA is 30Hz and
the desired pump speed at 20mA is 65Hz, set the Offset to 30 Hz and the Span to 35Hz.
• You will be asked if want to use 2-Wire Stop/Start control. If you choose yes, the 2WireRunStop Wizard
will be executed from within the PLC Analog Control Wizard. See information on 2-wire Stop/Start Wizard
below.
This wizard changes the Drive Mode to
“Analog Follower”. To restore local frequency control, change the
Drive Mode to
“Manual Frequency” or any other Drive Mode. (Settings -> Menu ->Set Drive Mode->Drive
Mode). The Drive Mode setting does not affect operation of the 2-Wire Run/Stop feature.
5.12
2-Wire Run/Stop
2-Wire Run/Stop allows an external controller to control motor start/stop using a digital input. Execute the
2WireRunStop wizard to put Apollo into this
“dumbed down” mode.
To execute the wizard, from the Home Screen select:
Settings -> Menu -> Other Initial Setup -> Next Page -> Next Page -> Configuration Wizards ->
2WireRunStop.
Follow the on-screen directions.
Information needed by the 2WireRunStop wizard:
• Digital Input used to Start and Stop the drive. Options are V7 Digital S1, V7 Digital S2, EIO Digital
Option 1, EIO Digital Option 2.
• Digital Input used to enable or disable Start/Stop control (optional). Options are HMI Dig In 1, HMI Dig
In 2, V7 Digital S3, V7 Digital S4, EIO Digital 3 and EIO Digital 4.
Содержание Apollo 3
Страница 1: ...Copyright 2020 Baker Hughes Company All rights reserved Page 1 of 277...
Страница 46: ...Copyright 2020 Baker Hughes Company All rights reserved Page 46 of 277 Figure 20 Backspin Probes Drawing 2...
Страница 139: ...Copyright 2020 Baker Hughes Company All rights reserved Page 139 of 277 Figure 116 Murphy Switch Trigger Example 1...
Страница 266: ...Copyright 2020 Baker Hughes Company All rights reserved Page 266 of 277 Figure 227 USB Menu...
Страница 267: ......
Страница 276: ......
Страница 277: ...Index 129112 28 197705 28 197349 28 800638 28 197350 28 810280 28 197351 29...