Screen data on the Digital IO screen shows the current state of all the digital inputs and outputs
in the system.
• Digital I/O Name
– V7 Dig In x indicates an input on the drive power module.
– HMI Dig In x indicates an input on the HMI.
– EIO Dig Opt x indicates a digital I/O on the Apollo I/O board.
The Digital I/O Name will normally be changed to reflect the meaning of the input
or output.
• Value Field Digital Inputs
– False: Digital Input is in its inactive state (e.g., a Normally Open contact is open, or
a Normally Closed contact is closed.)
• True – Digital Input is in its active state (e.g., a Normally Open contact is closed, or a
Normally Closed contact is open.) Digital Outputs
– 0 indicates the relay is OPEN. If the Digital Output is configured as Normally Open, the
controlling trigger is CLEAR. If the Digital Output is configured as Normally Closed, the
controlling trigger is SET.
– 1 indicates the relay is CLOSED. If the Digital Output is configured as Normally Open,
the controlling trigger is SET. If the Digital Output is configured as Normally Closed, the
controlling trigger is CLEAR.
Содержание Apollo 3
Страница 1: ...Copyright 2020 Baker Hughes Company All rights reserved Page 1 of 277...
Страница 46: ...Copyright 2020 Baker Hughes Company All rights reserved Page 46 of 277 Figure 20 Backspin Probes Drawing 2...
Страница 139: ...Copyright 2020 Baker Hughes Company All rights reserved Page 139 of 277 Figure 116 Murphy Switch Trigger Example 1...
Страница 266: ...Copyright 2020 Baker Hughes Company All rights reserved Page 266 of 277 Figure 227 USB Menu...
Страница 267: ......
Страница 276: ......
Страница 277: ...Index 129112 28 197705 28 197349 28 800638 28 197350 28 810280 28 197351 29...