Table 44: Miscellaneous Settings
Name
Location
Description
Max Start Time
Home Screen ->
Settings ->
Menu -> Other Initial Setup
(page 3)
The maximum acceptable
delay between sending a start
command to the drive power
module and detecting that the
drive is running.
If the Max Start Time is exceeded,
Apollo will report a Start Failed.
Default value is 8 seconds.
Pre-Start Delay
Home Screen ->
Settings ->
Menu -> Other Initial Setup
(page 3)
The minimum time that Apollo
remains in the Prepare2Start
state. Note that Apollo can
remain in the Prepare2Start state
longer if there is an active trigger
with action
“Hold in Prestart”. An
example of a
“Hold in Prestart”
trigger would be charge pump
minimum pressure trigger in an
SPS system.
The default value is 2 seconds.