Table 8: Digital Input and Output Modules (cont'd.)
Description
Part Number
Voltage Range
Max Output
Current Input
Impedance
Color
AC Output
Module
800864
24 to 280 Vac
1.5 Amperes
Black
Relay (Dry
Contract) Output
Module
801633
120 Vac/100 Vdc
1.5 Amperes
Red
These modules are installed in the IO 1
–IO 12 sockets on the I/O board. The picture below
shows how a DC Input Relay module would be installed.
Figure 6: DC Input Relay Install
The Digital I/O is configured as inputs or outputs in the Apollo System. By default, Digital I/O
are configured in the Apollo system as inputs¹. Set an I/O as an output by connecting it to the
desired Trigger using the
“Connect this Trigger to a Digital Output” selection on the Trigger Info
Section 5.15 Add a 2nd IO Board, page 165
for more details.
¹There is an exception to the
“input by default” rule. In the switchboard template, Digital I/O 7
is set by default as an output and connected to the Contactor On trigger used to start and
stop the motor.
3.2.3
Downhole Sensor Interface (DSI) Assembly
The Osiris Downhole Sensor Interface (DSI) Assembly works in conjunction with a Baker
Hughes supplied Osiris Downhole Tool to acquire well information and communicate that
information to
Содержание Apollo 3
Страница 1: ...Copyright 2020 Baker Hughes Company All rights reserved Page 1 of 277...
Страница 46: ...Copyright 2020 Baker Hughes Company All rights reserved Page 46 of 277 Figure 20 Backspin Probes Drawing 2...
Страница 139: ...Copyright 2020 Baker Hughes Company All rights reserved Page 139 of 277 Figure 116 Murphy Switch Trigger Example 1...
Страница 266: ...Copyright 2020 Baker Hughes Company All rights reserved Page 266 of 277 Figure 227 USB Menu...
Страница 267: ......
Страница 276: ......
Страница 277: ...Index 129112 28 197705 28 197349 28 800638 28 197350 28 810280 28 197351 29...