Copyright 2020 Baker Hughes Company. All rights reserved.
Page 71 of 277
3.8.6
Amp Chart Screen
Figure 39: Amp Chart Screen
Function:
The Amp Chart screen displays one day or seven days of drive output current data in the familiar
circular format. Data is saved based on a dead band algorithm up to once per second.
Screen Data:
Screen data on the Amp Chart screen shows the drive output current in Amps.
• Amp Chart Date
• Graphical Output
• Outer Ring – Amps at the outer ring of the chart
• Each Ring – Amps per minor division
Keypad Functions:
F1:
“Data” – Display the next data display screen.
F2:
“Home” – Closes the current screen and displays the Home screen.
F3:
“Settings” – Access drive settings that can be changed.
F4:
“Events” – Activates the Event Log screen containing the 4096 newest events.
F5:
“Graphs” – View historical graphs of the data shown on this page.
Arrows:
• Up, Down – Change the chart format between 1 and 7 days.