Copyright 2020 Baker Hughes Company. All rights reserved.
Page 232 of 277
Table 61: Enable States
Enable State
Description
STOPPED States
Check if you wish the trigger to be enabled when
the drive is stopped. Stopped motor control states
include Initializing, Locked Out, Fault, No Restart,
Hold, and Restart. See Note 1.
Prepare2Start
Check if you wish the trigger to be enabled during
the startup sequence. The motor control state
associated with this is Prep to Start (non ESP
templates) or Wait Backspin (ESP templates).
STARTING State
Check if you wish the trigger to be enabled during
the STARTING state.
RUN MODE 1
Check if you wish the trigger to be enabled when
the drive is in Running.
Note that you can use the different run modes to
have different active
triggers… i.e. you can create
multiple underload triggers and have them enabled
in different run states to better protect your system.
RUN MODE 2
Check if you wish the trigger to be enabled when
the drive is in RUN MODE 2.
RUN MODE 3
Check if you wish the trigger to be enabled when
the drive is in RUN MODE 3.
If a trigger has been enabled in all states AND has an enable delay set, then it will be disabled in
the STOPPED States.
10.7
Trigger Screens
Trigger Info Screen
Shown as logged in at Level 2.
Trigger parameters that can be edited from this screen are:
• Trigger Limit
• Trigger Action
• Enable Delay
• Trip Delay
• Restarts Allowed
Содержание Apollo 3
Страница 1: ...Copyright 2020 Baker Hughes Company All rights reserved Page 1 of 277...
Страница 46: ...Copyright 2020 Baker Hughes Company All rights reserved Page 46 of 277 Figure 20 Backspin Probes Drawing 2...
Страница 139: ...Copyright 2020 Baker Hughes Company All rights reserved Page 139 of 277 Figure 116 Murphy Switch Trigger Example 1...
Страница 266: ...Copyright 2020 Baker Hughes Company All rights reserved Page 266 of 277 Figure 227 USB Menu...
Страница 267: ......
Страница 276: ......
Страница 277: ...Index 129112 28 197705 28 197349 28 800638 28 197350 28 810280 28 197351 29...