5.17
Add a Data Display Screen to the Level 1 Data Screen Rotation
By default, the only Data Display screens in the Level 1 Data rotation are the Downhole Sensor screen, the
Digital I/O screen, the Analogs screen, and the Amp Chart screen. In some cases, it may be desirable for
other screens to be added to the Level 1 Data rotation.
1. Log on as level 2 or level 3.
2. Navigate to the Edit Screens Menu wizard.
a. Home Screen -> Settings -> Menu -> Other Initial Setup -> Right Arrow -> Right Arrow ->
Configuration Wizards -> Set Level1 Screens
3. A list of screens appears with a check mark next to each screen. A check mark indicates that the screen
is in the Level 1 Data Screens rotation. Use the Right and Left Arrow buttons to move between pages.
Use the Up and Down Arrow buttons to highlight the screen you wish to be in the Level 1 Data Screens
rotation. Use the check mark function button (F4) to set or clear the check boxes as desired.
Figure 138: Adding Screens to Level 1 Data Screen
4. In this example, the Custom Screen 1 has been checked so that it will be in the Level 1 Data Screen
rotation. Press Continue to finish the wizard.
The Custom Screen 1 will now appear in the Level 1 Data Screen rotation.
5.18
Add or Delete a Setting in the Settings Rotation
By default, the only Settings in the Level 1 settings rotation are the Speed Setpoint and the Color Scheme.
Level 2 and Level 3 users have access to more settings in the settings rotation. Level 2 and Level 3
users can add or remove parameters Settings rotation and control which are available to Level 1 users
using the Edit Settings wizard.
1. Log on as level 2 or level 3.
Содержание Apollo 3
Страница 1: ...Copyright 2020 Baker Hughes Company All rights reserved Page 1 of 277...
Страница 46: ...Copyright 2020 Baker Hughes Company All rights reserved Page 46 of 277 Figure 20 Backspin Probes Drawing 2...
Страница 139: ...Copyright 2020 Baker Hughes Company All rights reserved Page 139 of 277 Figure 116 Murphy Switch Trigger Example 1...
Страница 266: ...Copyright 2020 Baker Hughes Company All rights reserved Page 266 of 277 Figure 227 USB Menu...
Страница 267: ......
Страница 276: ......
Страница 277: ...Index 129112 28 197705 28 197349 28 800638 28 197350 28 810280 28 197351 29...