Installing IP500/IP500 V2
Page 267
15-601042 Issue 28c (19 August 2013)
IP Office 9.0
System Components: IP400 Expansion Modules
Module Rear
Ports
Description
ANALOG
RJ45 socket. Used for connection to analog trunks. Ports can be configured as either loop-start or
ground-start trunks through the IP Office configuration.
In the event of power failure, Analog ports 1 and 2 are directly connected to analog extension ports
PF1 and PF2 respectively. If used the connected phones must be clearly labeled as power failure
devices. This is only supported for loop-start analog trunks.
DC I/P
DC power input port. Used for connection of the power lead from an Avaya 40W external power supply
unit supplied with the expansion module. A locale specific
IEC60320 C7 power cord
for the
external PSU is required but is not supplied with the module.
DTE
25-Way D-Type socket. For Avaya use only.
EXPANSION
RJ45 Socket. Used for direct connection to an Expansion port on an IP Office control unit using the
Expansion Interconnect cable supplied with the module.
PF
RJ45 socket. Power failure analog extension ports. See Analog section above.
Ground point. Used for connection of a
functional earth
if required. On older modules where this
screw is not present, the top-center cover screw should be used instead.
·
IMPORTANT
In all IP Office installations, any module being used for analog trunk connections must be connected
to a
functional earth
.
·
WARNING
Within the Republic of South Africa and in areas of high lightning risk, any module using analog
trunk connections must be connected to a
protective ground
and to
surge protection equipment
.
Part Codes and Related Equipment
All expansion modules are supplied with a base software level and should be upgraded to match the core software of the
control unit in the IP Office system. Expansion modules include an external power supply unit (PSU) and an appropriate
interconnect cable. They do not include a locale specific power cord for the external PSU or any phone extension cables.
Item
Variant
Country
SAP Code
IP400 Analog Trunk 16
America
America
700211360
Europe
Europe
700241680
New Zealand
New Zealand
700241698
IEC60320 C7 Power Cord
CEE7/16
Europe
700213382
BS1363
United Kingdom
700213374
NEMA1-15
America
700213390
Korea
Korea
700254519
IP400 Rack Mounting Kit
All
700210800
390
393
39
395
397
44
44
44
45
Содержание IP500
Страница 1: ...15 601042 Issue 28c 19 August 2013 Installing IP500 IP500 V2 IP Office 9 0 ...
Страница 10: ......
Страница 11: ...Installing IP500 IP500 V2 Page 11 15 601042 Issue 28c 19 August 2013 IP Office 9 0 System Overview Chapter 1 ...
Страница 12: ......
Страница 58: ......
Страница 117: ...Installing IP500 IP500 V2 Page 117 15 601042 Issue 28c 19 August 2013 IP Office 9 0 On Boarding Chapter 6 ...
Страница 120: ......
Страница 121: ...Installing IP500 IP500 V2 Page 121 15 601042 Issue 28c 19 August 2013 IP Office 9 0 SD Card Management Chapter 7 ...
Страница 132: ...Installing IP500 IP500 V2 Page 132 15 601042 Issue 28c 19 August 2013 IP Office 9 0 ...
Страница 138: ...Installing IP500 IP500 V2 Page 138 15 601042 Issue 28c 19 August 2013 IP Office 9 0 ...
Страница 143: ...Installing IP500 IP500 V2 Page 143 15 601042 Issue 28c 19 August 2013 IP Office 9 0 Additional Processes Chapter 8 ...
Страница 187: ...Installing IP500 IP500 V2 Page 187 15 601042 Issue 28c 19 August 2013 IP Office 9 0 IP500 Basic Installation Chapter 9 ...
Страница 209: ...Installing IP500 IP500 V2 Page 209 15 601042 Issue 28c 19 August 2013 IP Office 9 0 System Components Chapter 10 ...
Страница 422: ......
Страница 423: ...Installing IP500 IP500 V2 Page 423 15 601042 Issue 28c 19 August 2013 IP Office 9 0 Safety Statements Chapter 11 ...
Страница 434: ......
Страница 440: ......
Страница 441: ...Installing IP500 IP500 V2 Page 441 15 601042 Issue 28c 19 August 2013 IP Office 9 0 ...