![Autodesk 22505-051400-9000 - AutoCAD Electrical 2008 Скачать руководство пользователя страница 927](http://html1.mh-extra.com/html/autodesk/22505-051400-9000-autocad-electrical-2008/22505-051400-9000-autocad-electrical-2008_user-manual_3021135927.webp)
in the project set. Then it displays a location list dialog box where you can
make your report's "from" and "to" location selections. All the location codes
AutoCAD Electrical found on the drawing set are listed on each side of this
dialog. Location "(??)" is also included in the list if AutoCAD Electrical found
any component or stand-alone terminal that didn't have an assigned location
code.
Access:
Click the Schematic Reports tool. Select Wire From/To from the report list.
From the Projects menu, select Reports
➤
Schematic Reports. Select Wire
From/To from the report list.
Specify whether to process the project, the active drawing, or selected wires.
List
Lists drawings that appear to be out-of-date with the project's wire connection
table.
Freshen Wire Connection Table
Specifies for AutoCAD Electrical to update the wire connection table to include
any out-of-date drawing files.
Format
Changes the format of the extracted data. The dialog box lists the format files
to select from.
Schematic PLC I/O address and descriptions
This report lists each PLC module and its beginning and ending I/O address
numbers. It scans your drawing set and returns all individual I/O connection
points it finds. This includes up to five lines of description text and the
connected wire number for each I/O point.
Click the Schematic Reports tool. Select PLC I/O Address and Descriptions
from the report list.
Generate schematic reports | 915
Содержание 22505-051400-9000 - AutoCAD Electrical 2008
Страница 1: ...AutoCAD Electrical 2008 User s Guide February 20 2007 ...
Страница 4: ...1 2 3 4 5 6 7 8 9 10 ...
Страница 79: ...command is invoked AutoCAD Electrical automatically inserts this block at 0 0 Create a new drawing 67 ...
Страница 106: ...94 ...
Страница 228: ...216 ...
Страница 242: ...HP W TERM_ VDC SPECIAL SPACINGFACTOR 0 5 HP WA D TERM_ 02 230 Chapter 5 PLC ...
Страница 294: ...282 ...
Страница 564: ...552 ...
Страница 698: ...686 ...
Страница 740: ...728 ...
Страница 814: ...802 ...
Страница 1032: ...1020 ...
Страница 1134: ...1122 ...
Страница 1168: ...1156 ...
Страница 1177: ...Insert P ID Component Overview of pneumatic tools 1165 ...
Страница 1198: ...1186 ...
Страница 1269: ...AutoCAD Electrical Command In this chapter AutoCAD Electrical Commands 20 1257 ...
Страница 1304: ...Z zip utility 82 1292 Index ...