38
beep sound as a reminder whenever the data reading reaches the preset
minimum or maximum point.
To set threshold limits for the parameter values
1. Tap the
Setting
function button at the bottom of the Live Data screen.
2. Tap the
Selected
navigation button.
3. Select a parameter item on the left column, or enter the item name in the Search
bar.
4. Tap on the right side of the
MIN
button, and enter the required minimum value.
5. Tap on the right side of the
MAX
button, and enter the required maximum value.
6. Tap the
ON/OFF
button on the right side of the Buzzer Alarm button to turn it on
or off.
7. Tap
Done
to save the setting and return to the Live Data screen; or tap
Cancel
to exit without saving.
If the threshold limits are successfully set, two horizontal lines will display on each of the
data graphs (when Waveform Graph Mode is applied) to indicate the alarm point. The
threshold lines are displayed in different colors from the waveform of the parameters.
Record Button
— displays the configuration screen for Record Setting, to set the
trigger type, duration and trigger point for the data recording function.
a) Trigger Type
— sets the trigger mode for data recording, Manual and Auto.
There are four options available:
1) Manual
— manually starts and stops data recording.
2) DTC
— auto triggers data recording when any DTC is detected.
3) DTC Check Mode
— auto triggers data recording when certain pre-selected
DTC types are detected.
4) Parameter
— auto triggers data recording when any parameter value
reaches the preset threshold.
b) Duration
— sets the recording time (for Auto trigger mode only).
c) Trigger Point
— reserves a relative percentage of a record length before the
data recording start point for reference (for Auto trigger mode only).
To perform setting for live data record
1. Tap the
Setting
function button at the bottom of the Live Data screen.
2. Tap the
Record
navigation button.
3. Tap the
button on the right of
Trigger Type
bar and select the required
trigger mode.
4. Tap the
button on the right of
Duration
bar and select a length of time.
5. Tap the button on the right of
Trigger Point
bar and select a relative
percentage of a record length to be reserved before the data recording start
point.