background image

P/N:0000000000

CCA

BCI

CA

MCA

JIS

DIN

IEC

EN

SAE

Ah

12V/60Ah/CCA 500A

300A EN

12V 250Ah 60Ah DIN

26A19R 12V 60Ah

26A19RMF 12V 60Ah

12V/60Ah

CCA

EN

DIN

JIS#

JIS#

AH

500

300

250A

200

220

60Ah

Overview

UT673A/UT675A battery tester, with its leading-edge conductivity test technology, 
accurately and rapidly helps users to measure the cold cranking amps capability of the 
vehicle starting battery, healthy state of the battery itself, detect the common fault of 
vehicle starting and charging system, which helps repair vehicle quickly. 

Safety information

Please carefully read this manual and follow the warning and safety information before 
use.

  

To avoid fire and overcurrent, please read all rated values and symbol descriptions 

  

before use.

  

Do not open the case cover. Do not turn on the tester if its cover or front panel is open.

  

Do not touch the connectors and components if the tester is powered on.

  

Please contact the authorized repair personnel to detect, repair, maintain the tester 

  

if you find any fault on it.

  

Do not use in humid, explosive or inflammable environment.

  

Keep the tester surface clean and dry. Keep it well-ventilated.

Product introduction

Interface

UT673A

1) Battery: Battery test.
2) Crank: Vehicle Cranking system test.
3) 
4) Data: The last test result can be viewed.
5) Setting: Language setting.
6) About: View the system information.

Charge: Vehicle Charging system test.

UT675A

2) Crank: Vehicle Cranking system test.
3) 
4) Data: The last test result can be viewed or upload.
5) Print: Print test data.
6) Setting: Language and time setting, view the system information.

1) Battery: Battery test.

Charge: Vehicle Charging system test.

Feature

1) Applicable to 12V battery testing and 12V/24V vehicle cranking/charging system test.
2) Measurement standard and range:

100-2000

100-2000

100-2000

100-2000

26A17—245H52

100-1400

100-1400

100-2000

100-2000

30-200Ah

Measurement 

range

Measurement

standard

Measurement

standard

Measurement 

range

3) Working temperature: -20°C 50°C.
4) Special test clip: Double-conductor Kelvin clip.
5) Case material: Acid-resistant ABS plastic.
6) Measurement range of battery: 30Ah

200Ah.

7) Measurement range of voltage: 7V

16V.

8) Portable.

Example for  selecting standard

Battery identification

Standard

Battery 

parameter

Remark

12V battery, the capacity is 60Ah, 
the cold-start current is 500A.

The standard value is 300A.

12V battery, the capacity is 60Ah, 
the standard value is 250A.

12V battery, the capacity is 60Ah, 
check JIS CODE conversion table 
and find that 26A19R corresponds 
to 220A for CCA.

12V battery, the capacity is 60Ah, 
check JIS CODE conversion table 
and find that 26A19R corresponds 
to 220A for MF CCA.

If the standard is not found, 
estimate CCA value according to 
the battery capacity.

Operation instruction

1. Connect the red and black clips of tester to the measured battery, red is positive, 

   black is negative, the tester screen will display startup interface. If the battery voltage 
   is lower than 7.0V, the test will become abnormal.

2. According to the prompts, press up and down button to select:

UT673A:

 

① 

Battery test, 

② 

③ 

Charging test, 

④ 

View test results, 

Cranking test, 

               

⑤ 

System setting, 

⑥ 

About.

UT675A:

 

① 

Battery test, 

② 

③ 

Charging test, 

④ 

View test results, 

Cranking test, 

               

⑤ 

Print test result, 

⑥ 

Setting.

1. Make sure engine is off.

2. Connect to the correct polarity.

 

Battery        

Crank         

Charge

Data          

Setting       

About

 

Battery        

Charge

Data          

  

Print          

Setting

UT675A

UT673A

3. Select “Battery”

7. Press ENTER to start the test.

Description

The performance of storage battery is good, 
please continue using the battery.

Because the voltage of storage battery is lower 
than 12.3V, so the performance of storage 
battery is good, please continue using the 
storage battery after it is fully charged.

Because the battery voltage is lower than 12V, so please 
retest after it is fully charged. Incorrect reading may occur 
if the battery is not fully charged. Please replace the battery 
if “Retest after charging” displays again after charging.

The battery is in 

good condition.

The battery is in 
good condition, 
please charge 
the battery.

Retest after charging

Replace the battery

The battery is in bad 
condition, replace 
the battery.

Replace the storage battery.

Battery inside is damaged, replace the storage battery.

Battery capacity (SOC): The percentage of remaining battery capacity, 

1) 

2) Battery voltage (VOLTAGE): The voltage value of storage battery (Unit: V).

Battery life (SOH): State of health of battery storage, 

3) 

The measured cold-start current: The measured cold-start current of tester.

4) 

Nominal cold-start current: Nominal cold-start current of storage battery

5) 

Internal resistance of battery (R): The measured internal resistance of storage battery.

6) 

NOTE: For low-capacity battery (For example, the vehicle is shut down for a long 
time, the battery is not charged in time, the battery power is significantly lost 
because the vehicle door is not closed.), the tester may prompt you to “Replace 
battery” during actual measurement, please consult the storage battery factory 
and charge the battery according to the designated method, and then retest.

SOC=                                   ×100%.

Remaining capacity

Actual capacity

SOH=                               ×100%.

  Actual capacity

Nominal capacity

UT673A/UT675A Battery Tester

 

Battery        

Crank

        

Charge

Data          

Setting       

About

 

Battery        

Crank

        

Charge

Data          

  

Print          

Setting

UT675A

UT673A

Tests below are based on 12V, 60Ah, CCA580A:

1. Battery test

Crank         

Battery Test results

Interpretation

2. Cranking test

1. Make sure engine is off.

2. Connect to the correct polarity.

 

Battery        

Crank         

Charge

Data          

Setting       

About

 

Battery        

Charge

Data          

  

Print          

Setting

UT675A

UT673A

3. Select “Crank”

4. Enter the interfaceof 
    starting engine.

Crank         

NORMAL BAT.

AGM  ATTERY

B

EFB  ATTERY

B

GEL  ATTERY

B

TYPE

4. Select “NORMAL BAT”

CCA

DIN

JIS

EN

ST

ANDARD

5. Select standard,CCA for example.

580 A

CCA

SET RATING

6. Set rated capacity of battery.

TESTING

SOH           75

%

    

495A

SOC          100

%

   

12.8V

R=            3.35m

Ω

GOOD BATTERY

8. Display test result.

CRANKING TEST

START ENGINE

5. Start engine.

RPM DETECTED

CRANKING TEST

6. Engine RPM is detected.

TESTING

CRANKING   NORMAL

CRANKING   11.34V

TIME              243ms

7. Automatically enter the test. 

8. Display test result.

Reviews: