5. When the particle filter regeneration is complete, confirm to exit the display. Tap
Repeat
to recheck the status again or tap
End
to exit.
Figure 5-27
Sample Repeat Screen
NOTE
In the case of a particle filter heavily loaded with soot, it can occur that the regeneration
request is blocked again after a short time or is not released. Drive the vehicle for
approximately 30 minutes at a constant speed. Then perform the Particle filter
regeneration service again.
During the regeneration phase and with the engine running, it can also occur that the
display for “Regeneration active” jumps to “Regeneration not active”. This behavior can
be seen exclusively with the vehicle stationary with the engine.
Particle Filter Test
It is advisable to carry out a series of particle filter tests as a result of constant DPF
regeneration, such as checking oil level, oil change interval for diesel contamination, swirl
flaps, backpressure sensors and particle filter soot remains.
1. Tap
Particle filter test
from the service functions menu.
2. The tool communicates with the vehicle and reads the fault codes memory. If there
is no relevant fault code stored in DDE, the screen displays as below. Select
Cancel
to exit this function.
3. If there are DPF-related codes stored in DDE, the screen displays as below. Select
OK
to continue or
Cancel
to exit this function.