BRI Facilities
4–188
Programming Procedures
The timers are listed below.
■
T200 Timer.
Minimum time that the link layer waits for an
acknowledgement of a message sent from the communication system to
the network.
■
T203 Timer.
Maximum time that the link layer can remain inactive.
■
T303 Timer.
Times the delay in network response when the
communication system sends a setup message to initiate an outgoing
call.
■
T305 Timer.
Times the delay in network response when the
communication system sends a disconnect message to clear a call.
■
T308 Timer.
Times the delay in network response when the
communication system sends a release message to clear a call.
NOTE:
If you enter an invalid timer value, you will hear an error beep and the value that
was previously stored will be displayed on the screen.
Table 4–4 shows the factory setting for each timer and the valid range for each
threshold.
Summary: Timers
Programmable by
System manager
Mode
Key, Hybrid/PBX
Idle Condition
Not required
Planning Form
Factory Setting
Valid Entries
Inspect
No
Copy Option
No
Console Procedure
LinesTrunks
®
More
®
BRI
®
Timers
®
Select timer
®
Drop
®
Dial no. of seconds or ms
®
Enter
®
Exit
®
Exit
PC Procedure
4
®
u
®
8
®
2
®
Select timer
®
A
+
P
®
Type
no. of seconds or ms
®
0
®
5
®
5
Содержание MERLIN LEGEND Release 3.1
Страница 372: ...Memory Card 3 236 Common Administrative Procedures...
Страница 572: ...Telephones 4 200 Programming Procedures...
Страница 715: ...Memory Card Programming Procedures 4 343...
Страница 749: ...Feature Quick Reference 5 34 Centralized Telephone Programming...
Страница 773: ...Customer Support Information B 2 System Programming...
Страница 798: ...Button Diagrams E 6 System Programming...
Страница 800: ...Sample Reports F 2 System Programming Continued on next page...