System Features
3–180
Common Administrative Procedures
The recall timer should be reset if multiline telephone users experience either of
the following problems:
■
Nothing happens when the user presses the Recall button on an outside
call. This indicates that the interval is too short and should be increased to
650 milliseconds or 1 second.
■
In a system operating in Behind Switch mode, the call is disconnected
when the user presses the Recall button on an outside call. This indicates
that the interval is too long and should be decreased to 350 milliseconds.
Summary: Recall Timer
Programmable by
System Manager
Mode
All
Idle Condition
Not required
Planning Form
Form 8a, System Features
Factory Setting
450 ms
Valid Entries
350 ms, 450 ms, 650 ms, 1 second
Inspect
No
Copy Option
No
Console Procedure
Options
®
More
®
RecallTimer
®
Select time
®
Enter
®
Exit
PC Procedure
7
®
u
®
3
®
Select time
®
0
®
5
Procedure: Recall Timer
Console Display/Instructions
Additional Information
PC
1
Select the Options menu.
System Programming:
>
Make a selection
System
Extensions
SysRenumber
Options
_
Operator
Tables
LinesTrunks
AuxEquip
Exit
NightSrvce
7
2
Go to the second screen of the Options menu.
Options:
>
Make a selection
Transfer
Callback
CampOn
Ext Status
CallParkRtn
SMDR
Delay Ring
InsideDial
Exit
ReminderSrv
Press
More
.
u
Содержание MERLIN LEGEND Release 3.1
Страница 372: ...Memory Card 3 236 Common Administrative Procedures...
Страница 572: ...Telephones 4 200 Programming Procedures...
Страница 715: ...Memory Card Programming Procedures 4 343...
Страница 749: ...Feature Quick Reference 5 34 Centralized Telephone Programming...
Страница 773: ...Customer Support Information B 2 System Programming...
Страница 798: ...Button Diagrams E 6 System Programming...
Страница 800: ...Sample Reports F 2 System Programming Continued on next page...