Optional Telephone Features
Programming Procedures
4–215
ARS Restriction Level For Extensions
Use this procedure to assign an ARS restriction level to an extension. Only
outgoing calls are affected; users can receive inside, local, and toll calls on
restricted telephones and can join any type of call in progress. In order to use a
route a caller at an extension must have a Restriction Level that is equal to or
greater than the Facility Restriction Level (FRL) for the route. The restriction level
assigned to extensions is opposite to the FRL assigned to routes, where 0 is the
most and 6 is the least restrictive.
Summary: Assigning ARS Restriction Level For
an Extension
Programmable by
System manager
Mode
Hybrid/PBX only
Idle Condition
Not required
Planning Form
Form 4b, Analog Multiline Telephone
Form 4d, MLX Telephone
Form 4e, MFM Adjunct: MLX Telephone
Form 4f, Tip/Ring Equipment
Form 5a, Direct-Line Console (DLC): Analog
Form 5b, Direct-Line Console (DLC): Digital
Form 5c, MFM Adjunct: DLC
Form 6g, Call Restriction Assignments and Lists
Factory Setting
3 (ports assigned as VMI Generic or VMI Integrated are
maximally restricted with an FRL of 0)
Valid Entries
0-6, (0 is most restrictive and 6 is least restrictive)
Inspect
No
Copy Option
No
Console Procedure
Extensions
®
More
®
ARS Restrict
®
Dial ext. no.
®
Enter
®
Drop
®
Dial restriction level
®
Enter
®
Exit
PC Procedure
6
®
u
®
6
®
Type ext. no.
®
0
®
A
+
p
®
Type
restriction level
®
0
®
5
Forced Account Code Entry
Use this procedure to assign or remove Forced Account Code Entry. When this
feature is programmed on individual telephones, the user must enter a 1- to 16-
digit account code before making an outside call.
Содержание MERLIN LEGEND Release 3.1
Страница 372: ...Memory Card 3 236 Common Administrative Procedures...
Страница 572: ...Telephones 4 200 Programming Procedures...
Страница 715: ...Memory Card Programming Procedures 4 343...
Страница 749: ...Feature Quick Reference 5 34 Centralized Telephone Programming...
Страница 773: ...Customer Support Information B 2 System Programming...
Страница 798: ...Button Diagrams E 6 System Programming...
Страница 800: ...Sample Reports F 2 System Programming Continued on next page...