background image

The SP-02 speaker phone 

1/2 

MJV51103_OS2 

The SP-02 speaker phone  

 

 
 The SP-02 half-duplex speaker phone allows 
a caller (user, a central monitoring station 
operator etc) to talk and listen-in to the 
monitored premises. It should be connected to 
a communicator equipped with a simulated 
telephone line (e.g. JA-80Y) or to an analog 
phone line. 
   
Since the SP-02 only automatically answers 
phone calls from up to 8 authorized phone 
numbers, the phone line must support caller 
identification (CLIP) (from unauthorized phone 
numbers it is possible to answer the call 
manually by pressing a button on the SP-02. 
Programming can be locked by a 4-digit user 
code. 

 

1. Installation 

 

 

Connect the SP-02 to the phone line and insert its batteries (2x 1.5V AA). If the batteries do not have too low 
a voltage, the SP-02 is ready for operation which is indicated by the green indicator flashing. If the red 
indicator flashes, then the batteries are discharged and it is necessary to replace them (only use quality 
alkaline batteries).  
Before first usage, the SP-02 must be set up as follows: 

 From any phone, make a call to the SP-02’s phone number. As soon as the red indicator starts flashing 

press the button to answer the call.  

  On your phone press the * key to enter the setting mode and make settings according to the table below. 

NOTE: the * key is also accepted as a valid symbol in the setting sequence. 

 Terminate the call 

 

Sequence Function 

¿¿

 

To store a current caller’s phone number to position number 

¿

Dxxxxxxxx

¿

 

Phone number memorization (7 to 22 digits),  
D  is the phone number memory reference (1-8) 
The SP-02 automatically answers calls from memorized 
phone numbers   

¿

D

¿

 

 To erase a phone number in memory D 

¿

9xxxx

¿

 

Setting the user code and locking the SP-02 – first set at 
least one phone number ! 

#xxxx 

Unlocking the SP-02 

Setting table 

Note: 
Correct setting and storing of the sequence is confirmed by 1 beep. If the setting was not done correctly the 
SP-02 makes 4 beeps, and if there is a fault (e.g. due to a low battery) 10 beeps sound. 
 When the user code has been set, the SP-02 is automatically locked. To enter setting mode again the SP-02 
must be unlocked first.  
If locked, the calls from 

unauthorized

 phone numbers cannot be answered by pressing the button on the SP-

02. 
Warning: If the SP-02 is locked and no phone number has been memorized then further 
communication is impossible. In such a case, a reset of the SP-02 must be performed.  

 

button

microphone

LED

Отзывы: