The SP-02 speaker phone
1/2
MJV51103_OS2
The SP-02 speaker phone
The SP-02 half-duplex speaker phone allows
a caller (user, a central monitoring station
operator etc) to talk and listen-in to the
monitored premises. It should be connected to
a communicator equipped with a simulated
telephone line (e.g. JA-80Y) or to an analog
phone line.
Since the SP-02 only automatically answers
phone calls from up to 8 authorized phone
numbers, the phone line must support caller
identification (CLIP) (from unauthorized phone
numbers it is possible to answer the call
manually by pressing a button on the SP-02.
Programming can be locked by a 4-digit user
code.
1. Installation
Connect the SP-02 to the phone line and insert its batteries (2x 1.5V AA). If the batteries do not have too low
a voltage, the SP-02 is ready for operation which is indicated by the green indicator flashing. If the red
indicator flashes, then the batteries are discharged and it is necessary to replace them (only use quality
alkaline batteries).
Before first usage, the SP-02 must be set up as follows:
•
From any phone, make a call to the SP-02’s phone number. As soon as the red indicator starts flashing
press the button to answer the call.
•
On your phone press the * key to enter the setting mode and make settings according to the table below.
NOTE: the * key is also accepted as a valid symbol in the setting sequence.
•
Terminate the call
Sequence Function
¿¿
To store a current caller’s phone number to position number
1
¿
Dxxxxxxxx
¿
Phone number memorization (7 to 22 digits),
D is the phone number memory reference (1-8)
The SP-02 automatically answers calls from memorized
phone numbers
¿
D
¿
To erase a phone number in memory D
¿
9xxxx
¿
Setting the user code and locking the SP-02 – first set at
least one phone number !
#xxxx
Unlocking the SP-02
Setting table
Note:
Correct setting and storing of the sequence is confirmed by 1 beep. If the setting was not done correctly the
SP-02 makes 4 beeps, and if there is a fault (e.g. due to a low battery) 10 beeps sound.
When the user code has been set, the SP-02 is automatically locked. To enter setting mode again the SP-02
must be unlocked first.
If locked, the calls from
unauthorized
phone numbers cannot be answered by pressing the button on the SP-
02.
Warning: If the SP-02 is locked and no phone number has been memorized then further
communication is impossible. In such a case, a reset of the SP-02 must be performed.
button
microphone
LED